�� V' p`t�� �,d � s,�.`t j 13 <br />Simple Heating System Size: Washington State � <br />This heatinq svstem sizinq calculator is based on the Prescriptive Requirements of the 2012 Washinqton State Enerqv Code (WSEC) and ACCA <br />Manuals J and S. This calculator will calculate heatinq loads onlv. ACCA procedures for sizina coolina svstems should be used to determine coolinq <br />loads. <br />The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br />0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br />P�ease fill out all of the green drop-downs and boxes that are appiicable to your project. As you make selections in the drop-downs for each section, <br />some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension <br />Program at (360) 956-2042 for assistance. <br />Project lnformation Confact Information <br />Unit El Townhome Polygon NorthwesY <br />Siiver Lake Townhomes Alaina Robertson <br />Everett, Washin ton j425) 606-0005 <br />H@atl I1C� SySt@Il1 TyE7@: OO Forced Air Fumace Q Heat Pump <br />To see detailed instructions for each section, place your cursor on the word "Instructions". <br />Desiqn Temperature <br />�r;>trc«tions Design Temperature Difference (4T) <br />_ _ .__ _._ _-- _ <br />Everett JC <br />� _ _ _. .. _ _ ...___ . . _ _ ... �.: � OT = Indoor (70 degreesJ - Outdoor Design 7emp <br />Area of Buildinq <br />Conditioned Floor Area <br />i"S�ruct�°"5 Conditioned Floor Area (sq ft) <br />Average Ceiling Height <br />iirs2rucifens qverage Ceiling Height (ft) <br />Glazinq and Doors <br />InsFn�ctions <br />Insulation <br />Attic <br />_ _. _ <br />iti5il'UC60R> r_..—:... ._—_....� ..._.___.— "_��_____ �.._.._ ...:` <br />�` - R-44 � :` . i <br />�T <br />Single Rafter or Joist Vaulted Ceilings <br />IruYructio�s _-__ --_ <br />No Vaul[ed CelOngs In this proJect � ' <br />- � ��_�w ; <br />Above Grade Walls �aee Freure r� <br />insYructions �— --- --=Y . - + <br />R21 � J <br />�� <br />Floors <br />_ _ .__ ___._ <br />ii75tfUCiI0715 � '_'"_' ' ___ . ���_.�__ ._� . <br />% <br />� ,; R-30 � ` <br />Below Grade WaUs �s� Frgure �J <br />_ __ _ _ ____ _.__ . ___ <br />Insiructic�:> i .._-_._..__..__.._.._._____.._._ _._. _.._�..�,�___._. <br />� No Betow Grade Walls in thls pro)Kt �: <br />� ��,:�::.����_.� � �...�..`*;�e45+i��W <br />Slab Below Grade rsee F�a�re a� <br />_ _ __.__ <br />i��s.r,,�t�o„5 — — --- ----- ------ -- — <br />ho Slab Below Grade in this pro�e[t. �„,I <br />I .�z s-,,� �:� <br />Slab on Grade �see F�c�re n <br />irs�rui:tinns :::. _ : _.:______-�__ .__�;_.:� __..__— <br />R-10 Pe�imeter � !;. �, <br />;�,� �,.�';- <br />Location of Ducts <br />irstrc�ciions _ __ _ _. _._.._ __. . <br />� [ondiuoned Space �� � w ..� <br />�� — ���� <br />Fiqure 1. <br />���� <br />, '�, <br />� Above Grode <br />,, � <br />. '" .. '�Gr�de':.� .. _ . .. . _. <br />1,368 <br />Conditioned Volume <br />8.5 11,628 <br />U-Factor X Area = UA <br />0.30 9 81 54.42 <br />U-Factor X Area = UA <br />OA26 602 15.65 <br />U-Factor Area <br />-- � <br />U-Factor Area <br />0.056 413 <br />U-Factor Area <br />0.029 345 <br />U-Factor Area <br />� � <br />F-Factor Le� <br />UA <br />UA <br />23.13 <br />UA <br />10.01 <br />UA <br />UA <br />F-Factor Len th UA <br />0.540 66 35.64 <br />Duct Leakage Coefficient <br />1.00 <br />Sum of UA <br />138.85 <br />47 <br />Envelope Heat Load 6,526 Btu! Hour <br />Sum oI UA X �T <br />Air Leakage Heat Load 5,902 Btu / Hour <br />voiumex o.sxerx.o�a <br />Building Design Heat Load 12,428 Btu / Hour <br />Air Leakage + Envelope Hea! Loss <br />Building and Duct Heat Load 12,428 Btu ! Hour <br />Ducts /n unconditloned space: Sum of Building Heat Loss X 1.10 <br />Ducfs in conditioned space: Sum o( 8uilding Heat Loss X 1 <br />Maximum Heat Equipment Output 17,399 Btu / Hour <br />Building and Duct Heat Loss X 1.40 /or Forced Air Fumace <br />Building and Duct Heat Loss X 125 for Heat Pump <br />Y� (07/01/13J <br />