,From: Jeff Heilman jmailto:JHeilman@ci.everett.wa.us], <br />Sent: Monday, August 06, 2012 10:53 AM <br />To: 'Josh 0'Neil ' <br />Subject: RE: 1206 W Mukilteo Blvd <br />Josh, <br />A slab-on-grade in a basement is only required to be insulated ifi the floor is within 24" of the fiinished grade. <br />A slab on grade over a garage wauld be required to be insulated to min R-30 if using rhapter 6 table 6-1 prescriptive <br />Compliance. A slab-on-grade without a garage below is also required to be insulated to minimum R-10 on the exterior <br />ar R-1Q on the interior for 24 " at the perimeter. The other option is to raise the floor to provide adequate space fior R-30 <br />insulation. <br />Chapter 5 Component Performance Calculation can be used for the structure to offset the lacl< of insulation in any <br />companents. <br />Additions less than 750 S.F. can use "credits" obtained by upgrading the existing structure. <br />As far as the walls, existing residentiai occupancies can be insulated ta the depth of the existing cavity, R-15 in 2 x 4 <br />studs. New construc#ion ar a change af use (converting a garage into a living space) requires R-21 insulation in exterior <br />walls. <br />(f you are proposing to do a campanent p2rform�nc2 calculation, be advised that optian #2 of Table 6-1 is the required <br />Reference Case. The amaunt of "credit" when going from R-49 to R-6� is minimal. <br />if you hav� questions yau can reach me at the contacts below. <br />Jeff Heilman <br />Development Technician <br />City of Everett <br />Engineering/ Public Services Division <br />3200 Cedar Street, Everett WA 98201 <br />Phone 425-257-8976 <br />Fax 425-257-8857 <br />From: Josh 0'Neil [mailto:josh@oneilccinc.coml <br />Sent: Friday, August 03, 2012 3:40 PM <br />To: Jeff Heilman <br />Subject: 1206 W Mukilteo Blvd <br />Hello Jeff, <br />So my client closed on the above property and we opened some things up. When we all met at the city about a month <br />ago the thought was to bring the accessory dwelling unit up to the current WSEC (and do a few other things). Because <br />the whole thing is built on a sleeper floor system over concrete, half of which is slab on grade I'm wonder how the city <br />wants us to treat the floor insulation requirement. The sleeper is mostly 2x6. Obviously I can't get under the slab to <br />place a layer of rigid foam and the floor system isn't tall enough to allow for R-30. But I'm wondering how the city is <br />2� ' <br />