� <br />MODULAR BUILDING PAD 8� PIER FOU�tiUAi'ION DESIGN - FOUNDATION CALCULATI(UniS IBG2012 <br />CLIENT Pacific Mobile DEALER: Pacific Mobile Criteria 25psf-RLL,40psf-FLL,110mph, Exp <br />C, Cat-D, Ss=1.5, Fp=1500 psf <br />Date: 12-Dec-15 PO# E2015226 Location: KCDA Standards <br />Project #: 201501 # 27.1 28x32 MODULAR FDN-Classroom State(s): ID-OR-WA PNW <br />w/(2) Floor Joist Spans /Module <br />I. DESIGN CRITERIA: 28x32 MODULAR FDN-Classroom w/ 2 Floor Joist S ans /Module <br />Dead Load: Roof, RDL = 10 psf <br />1st Floor Ceiling CDL = 1 <br />E&M = 1 <br />Floor, FDL = 10 psf <br />Wall, WDL = 9 psf <br />Roof Live Load: Snow Load, RLL = 25 psf <br />Load Duration Factor, Cd = 1.15 % <br />Floor Load: Uniform Floor Load, FLL = Classroom 40 psf IBC Table 1607.1 <br />Concentrated Live Load, p= 1000 Ibs. IBC Table 1607.1 <br />Partion, PDL = 0 psf <br />Wind Load: Basic Wind Speed, V= 110 mph ASCE 7 Figure 26.5-1A <br />Building Risk Classification: Category II ASCE 7 Table 1.5-1 <br />Wind Importance Factor, Iw = 1.00 ASCE 7 Table 1.5-1 <br />Wind Directional Factor, Kd 0.85 ASCE 7 Table 26.6-1 <br />"a" Edge Pressure Distance = 3.00 ft <br />3 Roof Slope =�3 :12 = 14.04 Degrees <br />Edge Wind Pressure, Wep = 24.1 psf ASCE 7 Figure 28.6-1 <br />Interior Wind Pressure, Wip = 16 psf ASCE 7 Figure 28.6-1 <br />Average Wind Pressure, Wp = 17.74 psf ASCE 7 Figure 28.6-1 <br />Exposure Category = C� Exposure Factor, �= 1.21 ASCE 7 Figure 28.6-1 <br />Wind Topographic Factor, Kz = 1.00 ASCE 7 Section 6.5 <br />Design Wind Pressure , Pw = Wp°I�'Iw*Kz = 18.2 psf IBC Section 1605.3.1 <br />Average Uplift Wind Pressure, Wup = -19.6 psf <br />Seismic: Upper Modue Weight = 0.00 psf <br />Base Module Weight = 27.79 psf <br />Total Weight, Wtot = 27.79 psf <br />Snow Load % Used in Seismic Design = 0% <br />Soil Site Class D <br />Seismic Category = D PNW IBC Table 1613.3(1) <br />Mapped Spectral Accelerations, short periods, Ss = 1.5000 IBC Figure 1615 <br />Site Coefficient, Fa = 1.00 IBC Table 1615.1.2(1) <br />Max. Spectral Response, SMS= Fa�Ss = 1.50 IBC Equation 16-16 <br />Design Spectral Response, S�s = 2/3'SMs = 1.00 IBC Equation 16-18 <br />Response Modification Coefficient, R= 4.00 IBC Table 1617.6 <br />Lateral Load Factor, F=(1, Single Story; 1.1, 2-story; 1.2, 3-story) 1 ASCE 7-05, 12.14.8.1 <br />Total Shear, pst = F�SDS"Wtot/R = 6.95 psf ASCE 7-05 Equation 12.14.11 <br />Dimensions: Nominal Module Length, ML = 32 ft. <br />Nominal Module Width, MW = 14.00 ft. <br />Width, W= # Units = 2 28.00 ft. <br />Length, L= # Units = 1 32.00 ft. <br />1st Floor Wall Ht. = 9.00 ft. <br />2nd Flr. Wall Height, Wht = 0.00 ft. <br />Roof Height, Rht = 3:12 Slope 3.50 ft. <br />Floor Height above NG, Fht = 30 inches 2.50 ft <br />Building Ht Coeff, Htc = Rht+Wht+Fht-10 1.00 <br />No. of floor spans per module, nfs = 2 <br />Clear Distance between supports, L2a = 84.00 inches <br />2/22 201501.27-FDN-Calcs.xlsx PRINTED-12/12/2015 <br />