My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1211 PACIFIC AVE 2017-01-13
>
Address Records
>
PACIFIC AVE
>
1211
>
1211 PACIFIC AVE 2017-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 11:55:04 PM
Creation date
1/12/2017 3:16:36 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
1211
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
December 4, 2014 <br />Darrell Hay <br />darrellhay@aol.com <br />'UBL/E L�t/O/�/�CS <br />RE: Owner: Darli Properties LLC <br />Job Address: 1211 Pacific Ave <br />Plan Check No: B1412-002 <br />� � N s��- • <br />Dear Mr. Hay, <br />In response to your application for a� permit, your plans have been examined and you are advised <br />that revisions may be necessary before a permit can be issued. Please review and respond to the <br />comments below. These comments address building issues only. Additional revisions or additions may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the 2012 <br />International Building Code (IBC), the 2012 International Fire Code (IFC), the 2012 International <br />Mechanical Code (IMC), and the 2012 International Energy Conservation (IECC), as amended by the <br />State of Washington and adopted by the city of Everett. The current IBC referenced standard for <br />accessible design is the 2009 "Accessible and Usable Buildings and Facilities"(ICC/ANSI A117.1). Federal <br />ADA regulations and standards may be more restrictive. <br />In order for the processing of your application to continue, it will be necessary to provide the <br />Building Division with two complete new sets of construction documents reflecting the <br />corrections requested. <br />1. The plans should include all of the information necessary to verify compliance with IBC 716.5 <br />(fire door assemblies). Specifically, labeling to assure a 1 hour rating and maximum <br />transmitted temperature rise of not more than 450° F above ambient at the end of 30 <br />minutes of standard fire test exposure. <br />2. Please provide cross sectional details of proposed and existing exit enclosure walls including <br />fire protection rating and testing agency identification numbers. <br />If you have any questions, please call me at 425-257-7264. <br />Upon submittal of the drawings, your application will be given priority and plan reviews will recommence. <br />All required submittals shall be sufficient detail and contain sufficient information to ensure that the <br />proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, ! '�? ` <br />%� ,� ,�- � -` _ <br />Steve M�f(er <br />Associate Engineer <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8882 <br />
The URL can be used to link to this page
Your browser does not support the video tag.