My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10200 19TH AVE SE COSTCO OPTICAL 2022-01-26
>
Address Records
>
19TH AVE SE
>
10200
>
COSTCO OPTICAL
>
10200 19TH AVE SE COSTCO OPTICAL 2022-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:25:50 PM
Creation date
1/18/2017 12:58:57 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10200
Tenant Name
COSTCO OPTICAL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Treys Test File February 19,2014 <br /> Tag Data-Split System Air Conditioning Units (Small) (Qty: 1 <br /> Item Tag(s) Qty Description Model Number <br /> Al OU/IU-18 1 2.5 Ton Unitary Split Systems Heat 4TWR7024A1000A-GAM5BOB30M21SA <br /> Pump <br /> Product Data -Split System Air Conditioning Units (Small) <br /> Item: Al Qty: 1 Tag(s): OU/IU-18 <br /> 4TWR7 Heat Pump Outdoor Unit <br /> 2 Ton- Nominal Cooling Capacity <br /> Major design sequence <br /> 200-230 Volt 1 Phase 60 Hertz <br /> Good <br /> Multi-poise 4-way <br /> Better, Entry level Hi EFF, multispeed <br /> Major designs sequence <br /> 21.0"wide x 21.5"deep <br /> 2.5 Ton air handler <br /> Mid EFF Multi-speed <br /> Power Supply <br /> System Control Type <br /> Evaporator defrost control (Fld) <br /> 3.60/4.80 kW Electric Heater with Ckt Brk for 208/240V 1 Phase 60 Hz (Fld) <br /> 1st Year labor warranty <br /> Performance Data -Split System Air Conditioning Units(Small) <br /> Tags OU/IU-18 <br /> Design clg outdoor DB (F) 95.00 <br /> Cooling EDB(F) 80.00 <br /> Cooling EWB (F) 67.00 <br /> Rated gross capacity (AHRI) (Btuh) 24400.00 <br /> Clg net total capacity (Btuh) 24700.00 <br /> Clg net sensible capacity (Btuh) 18500.00 <br /> Clg net latent capacity (Btuh) 6200.00 <br /> Calc clg LDB (F) 58.30 <br /> Calc clg LWB (F) 56.90 <br /> SEER @ AHRI (btuh/watt) 16.00 <br /> EER @ AHRI (EER) 12.5 <br /> Cooling airflow(cfm) 800 <br /> Min system airflow clg (cfm) 700 <br /> Max system airflow clg (cfm) 900 <br /> Min system airflow htg (cfm) 700 <br /> Max system airflow htg (cfm) 900 <br /> Refrigerant line total length (ft) 20.00 <br /> Vertical refrigerant line length (ft) 20.00 <br /> AHRI airflow(cfm) 750 <br /> AHRI reference number() 6483560 <br /> Compressor power @ (specific Ambient) (W) 1681.0 <br /> Condenser fan power© (specific SP) (W) 121.0 <br /> Supply fan power© (specified SP) (W) 150.0 <br /> ASHRAE 90.1 S6.4.1 compliant Yes <br /> Htg outdoor DB (F) 30.00 <br /> Heating airflow(cfm) 800 <br /> Heating capacity @ 47F (Btuh) 23800.00 <br /> COP @ AHRI 47F (with Air Handler) (COP) 3.80 <br /> COP @ AHRI 17F (with Air Handler) (COP) 2.50 <br /> Heating capacity @ 17F (Btuh) 15000.00 <br /> HSPF @ AHRI (btuh/watt) 9.00 <br /> Heating EDB (F) 62.00 <br /> Htg system net capacity (Btuh) 17680.00 <br /> FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittalage' <br /> Installed by Others <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.