Laserfiche WebLink
( �. <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per Ciry Standard#601. <br /> � Connect side sewer per City Slandard #'s 601, 602,604. <br /> �§� /Connect all rooftop downspouts to lhe side sewer. ojl <br /> �/� " Connc�cl rooffop downspouts to the drainage syslem provided for this lol. <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltralion system per City of Everelt Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide, 2'deep and 25'long. See altachment tor <br /> more details. <br /> 9. The conlractor must meet with the Public Works Inspeclor to discuss potential drainage rouling prior to <br /> beginn(ng ihe projoct. <br /> 10. Inslall erosion controi measures as determined by the Public Works Inspector, such as silt(ence, slraw <br /> bales, swales, or erosion blankels. <br /> 11 Install eroslon conlrol measures per City of Everett Slandards for small parcels <br /> 12 Remove erosion control measures upon complelion of the project prlor to final approvai of lhe permit. <br /> 13. All excavated material(rom fuundation, sidewalk and driveways shall bt�hauled lo an approved, <br /> permitlod sile. No wasling of malerial is allowed on this building lot. <br /> 14� No dirt, mud, rocks or debris to be tracked onto roadway. <br /> .(�i°�E�nz�4� �1r71s�, <br /> 15. No building materials to bo stacked on�lewelks and s7dowalks to be kept clean and open for <br /> pedeslrian travel. <br /> 1G. Adjust water meler box 1"abovo sidewalk grado. <br /> 17. Remove and replace curb, c�uller and sidewalk as per City of Everett Standard Plan#'s 305A 8 306 0� <br /> lhis proposal's frontage as directecl by Ihe Public Works Inspector(i.e. all unused driveways and any <br /> brokon or damaged aroa musl be replaced). <br /> 18. Inslall a Type I concrolo driveway por City of Everett Slandard#307. <br /> � Pavo drivoway from Ihe(ront properly line out to tha slreet paving. <br /> 20. Contar,t tho Waler Districl for connecting provisions for lhis bullding's waler and <br /> sewer services. • <br /> 21. A catch basin as per City Standard Plan#402 with a gas trap per Standard Plan q410 is required for the <br /> parking area. <br /> 22. If a sewer pump syslem Is to be installod, Iho pressure line must discharge into a private manhole, then <br /> gravity flow across lhe public riglit-of-way. <br /> 23. A sprinkler systern is required for this building in compliance witli ihe requiremenls of NFDA Standards <br /> 13D. <br /> PWCommenis <br /> \� <br />