Laserfiche WebLink
� .� ;_, ,, r -. - „ ... .. z <br /> � COMPLIANCE ��E � 1 �J�7 i l�ip,� x��� �i r f eii� � �� ..� �i ��tl�ife�! � 1t �c3� C r 1«�1� �C�a�� <br /> i RE�UIRED � t <br /> ...r: . ., v..; � .;. . ,..1 a�_. i : , �i< • <br /> i <br /> INSPECTION �MpORTANI': Supply Inlormatlon and check approprlate circles In the shad'ed boxes.� <br /> APPROVED OlsreQerd toplcs that don't descrlbe your bulldlnp or equlpment.D.Q.�1D1 place checks In <br /> the two leR columns. <br /> �•�� � �� <br /> O O i� Prescrlptiv6 ezheuet ventliation exhaust requirements for each dwel8np unit (VIAQ, S. 303): <br /> � ' <br /> . . . .. ...:.. .. .._ ., ._.... .. :...... . . ......•. r..ne...:'... `"Cfj <br /> . . Minlmum(.25w.g.J MlrJmodel Fen label(.1W0) �;� <br /> „ Kitchen fan 100 CFM �' <br /> � Bathroom fan(_). 50 CFM �� <br /> ��; <br /> � Bathroom lan(_) 50 CFM ?:. <br /> � F���:. <br /> ��, <br /> Bathroomfan( ) 50CFM s �" <br /> � <br /> , Laundry lan 50 CFM � ; <br /> 50 CFM (1-2 bedrms) ��`: <br /> ts . . �?t�:' <br /> 80 CFM (3 bedrms) �`� <br /> �3_� <br /> 100 CFM (4 bedrms) <br /> Whole house leni Loaation ?' Sone ratin9 (K 1,5 H aftic fan c:loserthan 4`l0 <br /> celiing) � <br /> Q Whofe house tan is IlsledliablBd•lor Continuous use", <br /> Q Whole house fan wiring for conlrol routed to central bcatioq (dehum/d/stat only). , <br /> O O �e Whole houae fan also serves as a kitchen oc beth epatYaq. � Yea � No <br /> -(spotian designated as a whole house fan'shall meet whole house lan fequtrements.) <br /> O O �� Spot tan Isn't sufleble tor Whole house tan and must be seperate'Q Yes Q':No " <br /> O � �B Whole houae lan shall run condnuously: Kl2chen(25CFM);8ath�laundry(2UCfM)Q Yes �No '� <br /> p p +s Intepraled fo►ced-alrlumace ventllatlon(see laotnote)(VIAQ Code,'S.903.1.2(b))shall be <br /> synchronized with a whole house fan to supply tresh air to the dwetUng; p Yea � No <br /> °0 It yes, a s"dlameter outside air inlet duct w/rrwtorized tlamper enall�un from the uitding <br /> exterior fo the fumace retum plenum and Iimit the ventiUion rate to between.35 -.5"ACH, <br /> � Modlllcetlons to the above integrated forced alr system may require pertormance teeting, in a ' <br /> manner acceptable to the buikling oNicial, to demonstrate .36-,5 Air CherpesMour. <br /> 'Five bedrooms or larger requfres a designed whole house fan syslem(Rate7s .35 •.5 ACH) <br /> p p Q Mechanlcal ventllatlon fan ducts shall bo 2 4" ar,d properly sized (VIAO,Table 3-3). <br /> � , •, � <br /> O O Q Fresh alr ehaU be provided (or each dwelling Lnit as lollows(VIAq,S.302.8.1): <br /> ach bedroom: Tested,screened, controllabte,tfirough-wall port�: 4 Sq.in.}to lt�e e�terbr. <br /> O ach recreatlon room:One watl po�t as apecilled ior bedrooms. <br /> ther enclosed"habitable"rooms:One wall pori es specllied ior betlrooms. <br /> verall Ilving area: One wall port ns specilied lor bedrooms. <br /> O O QOR �Integrated forced alr turnace wh�h delivers oufslde makeup afr through the ducUng system <br /> WSEC Framing phase requlrements: <br /> Inspected by Dale pape s <br />