My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6617 ASSOCIATED BLVD BASE FILE 2018-01-02 MF Import
>
Address Records
>
ASSOCIATED BLVD
>
6617
>
BASE FILE
>
6617 ASSOCIATED BLVD BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 11:20:10 AM
Creation date
1/23/2017 10:35:56 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6617
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
173
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L;iL��retory ��nrt Fiol .' Tnstiny <br /> A. Concrete for precast stc�rnwater Veatment systems shall confortn to ASTM <br /> C 857 and C 858 and meet the following additional requiremenls: <br /> 1. The wall lhickness shall not be less than 6 inches (152 mm)or as sho,vn <br /> on the dimensional drawings. In all cases the wall thickness shall be no <br /> less lhan Ihe minimum thickness necessary to sustain HS20-44 (MS19) <br /> loading requirements as determined by a Licensed Professional Engineer. <br /> 2. Sections shall have tongue and groove or ship-lap joinls wilh A butyl <br /> mastic sealant confortning to ASTM C 990. <br /> 3. Cement shall be Type�I PorUand cement conforming to ASTM C 150. <br /> 4. All sections shall be cured by an approved method. Sections shail not be <br /> shipped unlil the concrele has allained a compressive slrength of 4,000 <br /> psi (28 MPa) or until 5 days aNer tabrication and/or repair, whichever is <br /> the longer. <br /> 5. Pipe openings shall be sized to accepl pipes of the specified size(s) and <br /> matenal(s�, and shall he sealed by lhe Contraclor with a hydraulic cement <br /> con(orming lo ASTM C:i95M <br /> B. Internal aluminum plate components shall be aluminum alloy 5052•H32 in <br /> accordance with ASTM B 209. <br /> C. Sealant to be ulilized at the base of the swirl chamber shall be GO durometer <br /> exiruded nitrile buladiene rubber (Bun2 N) and shall be provided to lhe <br /> concrete precaster for inslallation. <br /> D. Brick or masonry used to build the manhole trame to grade shall confortn to <br /> ASTM C 32 or ASTM C 139 and shall be installed in r,onformance with all <br /> local requiremenis. <br /> E. Casting for manhole frames and wvers shall be in accordance wilh ASTM <br /> A48, CL.308 and AASHTO M105. The manhale ireme and cover shall be <br /> equivalenl 10 Campbeil Foundry Pattem tl1009A or#1012D wstom cast w4h <br /> the CONTECH Stortnwater Solutions logo and (oplionally)tagline. <br /> F. A bitumen sealant in contormance with ASTM C 990 shall ba ulilized in the <br /> sealing of the joinl between the swid chamber and lhe vault at the long wall <br /> tangent points. The butyl material shall be 3/4-inch thick by 3/4•inch wide. <br /> 2.2 PERFORMANCE <br /> Each stormwater treatment system shall adhere lo the following peAormance <br /> specifications at lhe design treatment capacitiee,as listed below: <br /> Table 2. <br /> , Dealgn Treatment Sedlment <br /> Vortechs Mode��Y�;,` Capacity Storap� <br /> ��� c(s(Ils) yd�(m�) <br /> I 1000 0- 1.6(0-45) 0] (0.°4) <br /> � 2000 _ 1.6-2.B (45•AO) 1.2(0.91) <br /> 3000 2.B-4.5 (BO-125) 1.8(1.38) <br /> 4000 4.5-G.0 (125-175) 2.4(1.84) <br /> 5000 6.0-B.5 (175•240) 3.2(2.45) <br /> 7000 8.5- 11.0 (240-315) 4.0(3.06) <br /> 9000 11.0- 14.0(315-400) 4,8(3.67) <br /> 11000 14.0- 17.5(400-495) 5.6(4.28) <br /> 16000 17.5-25.0(495•710) 7.1 (5.43) <br /> `---- <br /> Each stortnwaler treatment system shall include a circular aluminum "swirl <br /> �2006 CONTECH Stormwater Solutions 125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.