, , � <br /> Page 2 , <br /> 2317 Baker <br /> 8 . Suoport or size all floor and ceiling joists in <br /> compliance with Section 2518 U.H.C. <br /> Electrical • <br /> 1. One additional 110 volt cunvenience outlet is requi.red <br /> in the northwest bedroom located in the north wall. • <br /> Plumbing <br /> 1. Provide a cleanout at stack. <br /> 2. Provide a vent at the shower. <br /> 3. Provide a cleaneut at the clothes washer waste. <br /> 4 . Correct improper connecti.on at the ABS to cast iron <br /> pipe. <br /> 5. Continue kitchen sink vent past the eave. <br /> 6. Provide a 2 inch waste at the kitchen sink. <br /> 7. Provide a 2 i.nch waste at the clothes washer. <br /> 8. Provide an approved relicf valve on the water heater. <br /> 9. Provide an approved gate valve on the water heater <br /> cold k�ater supply. <br /> 10. Remove non approved fittings. Install approved <br /> fittings in the waste line. <br /> 11. Install correct size of water piping. <br /> 12. {4ater piping shall be of one material. <br /> Upon recei�t of a letter stating you will comply with the abeve, <br /> a permit will be issued to repair and brinq this building to <br /> code. <br /> Yours truly <br /> � <br /> �'13Oa��` �''� <br /> Jamie G, Johnson <br /> Inspection Supervisor <br />