Laserfiche WebLink
CITY OF EUERETT <br /> BiiILnING INSPECTION DEPARTMEN7 <br /> (206) 259-8745 <br /> Gate Auaust 11 , 1986 <br /> Frans R. Thuyns <br /> 3207 Oakes <br /> Everett WA 98201 <br /> RE: Owner Ramona Bovlan <br /> Job Address Lots 28.29 Rucker Addn <br /> Plan Check No. 86/16911 <br /> In response to your application for a consLruction permit, your plans have been <br /> examined and you are;advised that the issuance of a permit is being withheld <br /> for the reasons iisted below. <br /> In order for processing of your application to continue, it will be necessary to <br /> provide the Building Department with two new sets of drawings reflecting the <br /> corrections requested . <br /> � Upon resubmittal of the drawings, your application will be given priority and <br /> plan review will recommence. <br /> Item No. <br /> 1 . Submit one copy of structural calculations including lateral design. <br /> 2, Framing under whirlpool tub is not clear. Furnish maximum weight of tub <br /> when fi11eA to capacity. <br /> 3. Most floor truss manufacturers require a 14" depth to limit deflection to 1 /160 <br /> for a 22 ft span. 12" depth is shown on Framing Plan. N11 214 is called for <br /> on Detail 16/9, 12" dimension on Detail 17/9. Nlease clarify. <br /> 4. Continuous vents are required at ridges and where roofs intersect walls . <br /> 5. Since insulation above most ceilings and in all wa11s is to have a continuous <br /> vapor barrier, an air-to-air heat exchanger will be required, <br /> 6, Stud wall in the basement is supporting three floors and a roof load. Tnis <br /> 15 not allowed by Table 25-R-3. Submit analysis or change type of wall . <br /> 7, Reinforcing for a basement wall should be o the inside (1 " clear) . <br /> E. Frets, Plans Examiner <br />