Laserfiche WebLink
4. <br />� <br />PUBLIC WORKS PERMIT COMMEN7 S <br />Connect side sewer per City Standard #601. <br />Connect side sewer per City Standard #'s 601, 602, 004. <br />6. Connect all rooftop downspouls to the side sewer. <br />7. Connect roof:op downspouts lo lha drainage syslem provided for this lot. <br />8. F2ooCop runoff musl be discharged to a roof downspout intiltratio� system per C�ty of Everett Storm <br />Manual 3-2.6.2. The appro>:�male size trench is 3.5' wide, 2' deep and 25' long. See ettachment for <br />more delails. <br />/ 9. � The contraclor must meet wi0i the Public Works Inspeclor to discuss poteNial draina�e routing prior lo <br />� beginning ihe project. <br />�0; <br />Install erosion conlrol measures as determined by the Public Works inspecror, such as silt tence, slraw <br />bales, swales, or erosion blankets. <br />Install erosion control measures per City of [verett Standards tor small parcels <br />Remove erosion control n:aasures upon completion of lhe projer,t prior lo final approval of the permit. <br />i 13. All excavated mate�ial from foundation, sidewalk and driveways shall be haul•=d tu an approved, <br />` permitled site. No wasting of material is allowed on this building iot. <br />� 14 <br />15 <br />16, <br />17 <br />1 f3 <br />19. <br />20 <br />21 <br />�._ <br />t�22 / <br />23 <br />No dirt, mud, rocks or debris lo be tracked onlo roadway. <br />No building malerials to be slacked on sidewalks and sidewalks to be kep� clean and open for <br />pedeslrian travel. <br />Adjust water meter box 1" above sidewalk grade. <br />Rnrnove and rep�ace curb, �utter and s�dewalk as per City of Everelt Standard Plan #'s 305A 8 306 on <br />Uiis proposal's frontac�e as directed by the Public Works Inspector (i.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />Install a Type I concrete driveway per City oi Evere�l Slandard #307. <br />Pave driveway (rom ihe front property line out to the slreet paving. <br />Contar.t the Water District for conneclin� provisions for this building's water and <br />sewer services. <br />A catch basin as per Cify Standard Plan #402 K:th a gas trap per Standard Plan #410 is required for the <br />parking area. <br />If a sewer pump system is to be installed, the pressure line must discharge inlo a private maNiole, then <br />gravity flow across the public right-o(-way. <br />A sprinkler system is required for Oiis building in compliance with ihe requirements of NFDA Standards <br />13D. <br />FOR PUGI_IC WORKS INSP�CTION, CALL RANDV AT 425-339-7403 / CLIFF AT 425-339-7404 <br />�� <br />