COMPLIANCE r r I , <br />REQUIRED <br />INSP[C'ION <br />APPRO CM IMPORTANT: Please supply Inlormatlon In the shaded boxes and check the appropriate <br />Er circles. Disregard topics that don't describe your building or equipment. DO -NOT place <br />checks In the two left columns. <br />` PHASE <br />❑ ❑ © Exterior Illab insulation, it not located on the interior, shall be R-10 (Table 6-2). <br />❑ ❑ QExtcrlor.slab Insulaiioo, it present, shall approved for below grade use and protected above grade. <br />❑ ❑ ®Walls, including rim joists, shall Insulated without compression to (Table 6-2): <br />OR-15 bait (Options 1,11) R-19 (Option III, IV, V, VI, VII) <br />❑ ❑ Qlnierl-- below grade walls shall be insulated without compression toff!2, <br />le 6.2): <br />OR-15 (Options I, 11) OR-19 (Options III, IV, V. Vt, VII) <br />El ❑ QVauited ceilings shall be insulated without compression to R-30 (Tab All options) <br />❑ ❑ Qi Skylight wall Insulation is installed and equivalent to the required wall R-values above. <br />❑ ❑ Q Vapor retarders shall be Installed toward the warm surface as represented below (502.1.6): <br />Select one option for floors, walls, and appropriate ceilings: <br />Floors: 0 Plywood W/ exterior glue KPoly (a 4 Mil) 0 Backed baits <br />Walls: oly plastic (a 4 Mil) 0 Face-st pled, backed baits 0 PVA paint <br />Ceilings: Not required where ventilation space averages >12" above insulation, <br />Face stapled backed baits 0Poly plastic (a 4 rill) 0 PVA paint <br />❑ ❑ rill Healing system efficiency and sizing requirements shall be met as represented below: <br />❑ ❑ t Heat Pump efficiency shall be met under the following compliance path (S, 503.4): <br />0 Split system, air source heat pump: HSPF a 6.8, COP > 3.0 <br />0 Single package, air, ource heat pump: HSPF a 6.6, COP > 3.0 <br />0 Water source heat pump: COP a 3.8 <br />0 Ground source heat pump COP a 3.0 <br />❑ ❑ QQ Central force -air furnace AFUE rating, as listed in the GAMA Directory, shall be: <br />Da .78 (Options I, 11, IV, VI, VII) a .88 (Option III)) 0a_74 (Option V) <br />❑ ❑ QQQQe Non -central, combustion heating systems shall have intermitent Ignition <br />❑ ❑ 71Maximum heating system output (150%of design heal load) Is-- BTU/hr. (S. 503.2.2) <br />❑ ❑ a�a High efficiency forced -air furnace (s 56,000 BTU/hr. output)may may exceed 15096of DHL <br />because: OGAMA listed AFUE is a 78 + i per each 5000 BTU/hr output that it exceeds the OHL. <br />__[-- ----- <br />WSEC Insulation phase requirements: <br />Inspected 6y: Date_ <br />x. <br />❑ ❑ 9 Envelope Floors shall be insulated without compression, and with <br />p p on s 24" O.C. to: <br />OR19 (Options 1, 11, 111, IV, V) 0 R25 (Options VI, VII) <br />❑ ❑ ro Non -vaulted, attic cell Ings shall be Insulated without compression See Table 6 2 <br />R-30 (Options 1, 11. 111, IV, V, VII) 0 R3B (Option VI) <br />❑ Elr+ Door ystems shall meet:MU.40 (All options) <br />Door types are (1)�—(2)---- --- ---- (3) -- - — - <br />Page 5 of 6 <br />