Laserfiche WebLink
f <br />C Cb70 2,D3 Z, <br />I. Provide co8stniction details/sections for guardrail system. Show <br />connectins <br />Commercial guardrail system noted rated to IRC 2003 specs of 200# lateral force <br />resistance added to drawing <br />2. Provide details/sections specific to this structure for each different type <br />of construction. Provide details for: <br />a. Roof construction and flashing. Show all components - <br />Added Detail <br />b. Connection of roof deck to floor flaming in loc. over living <br />space and garage. - Added Detail <br />c. Roof deck to exterior walls over living space - Added Detail <br />d. Footings and insulation at garage/residence - Added Detail <br />c. Footings at garage.Added Detail & Clarified <br />3. The foundation plan on Sheet 4 shows a different config than what is <br />shown on the main floor plan. Please clarify <br />Sheet 4 updated to match <br />Added <br />4. Provide 100 cfm exhaust fan vented to the exterior in the kitchen <br />5. 2 x 8 floor —joists do not provide sufficient depth, for the r-30 insulation <br />at mid level upper deck framing <br />Added notes for R-30 Spray in insulation this area <br />G. Locate bollard in garage such that all appliances protected from impact <br />Relocated <br />7. The plans show 4 risers from the garage to laundry room and details show <br />slab -on -grade <br />Corrected to show slab on grade <br />8. Provide safety glass in required locations per IRC Sec R308 <br />Added to Plans <br />9. Show how laundry room floor meets requirement if WSBC. R-30 <br />rcyyuired. <br />Clarified heated shd) detail <br />10. Revise 2006 IRC references -o 2003 IRC. <br />Revised. <br />Rob Clemens <br />Country Roads I Ionic Design <br />360-629-6068 <br />S -Z o --2 cj0`7 <br />