My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7405 BEVERLY LN 2016-01-01 MF Import
>
Address Records
>
BEVERLY LN
>
7405
>
7405 BEVERLY LN 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2017 9:41:47 PM
Creation date
1/23/2017 2:23:20 PM
Metadata
Fields
Template:
Address Document
Street Name
BEVERLY LN
Street Number
7405
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�l/�r</C L�f�'O � <br />February 18, 1'93 <br />Mr. Bob Champion <br />3802 Colby Avenue <br />Everett, Washington 98201 <br />RE: Owner: <br />Job Address: <br />Plan Check No <br />Doryan Construction <br />7405 Beverly Lane <br />B-39172 <br />In response to your application f��r a construction permit, your plans have been examined and <br />you are advised that the issuance of a permit is bemg w�thheld for the reasons listed below. <br />These comments address building issues only, additional revisions or additions may be <br />required by other depaztments (such as Utilities, Planning or Fire). All references refer to the <br />1991 Uniform Building Code, as amended by the State of Washington and/or Washington <br />State Energy Code 1991, 2nd Edition, unless stated otherwise. <br />Vl. Group R1 occupancies three or more stories in height or containing more than four <br />dwellirgs units or over 6,000 square feet (1'Z,000 square feet with area separation <br />walls) shall be equipped with an automatic fire suppression system (fire sprinklers) <br />per City Ordinance 1759-90. <br />2. Justifying test data in conformance with Section 107 shall be provided or an ICBO <br />evaluation report should be specified for exterior walls, umt separation walls, <br />ceiling/floor assemblies, ceiling/roof assembiies. <br />�(4t/G�. Rooms in which rubbish chutes terminate aze required to be separated from the <br />G�j�j� remainder of the building with at least 1-HR occu�ancy separadon, Section 1706(e). <br />The walls and ceiling of the trash room would service as the extension of the requ�red <br />shaft construction and any openings therein shall be provided with labeled assemblies. <br />Np �� 4. Parapet wall height and construction shal! be not less than indicated in Section 1710. <br />ojC,/G l This would apply to "bumps" at side yards. <br />�. Fire stops shall be defined on the plans. Firestopping location and materials shall <br />comply with Section 2516(�. <br />6. Draftstop shall be defined on the plans. Location and materials shall comply with <br />Section 2516(�. <br />CITY OF EVERETT• 3200 Cedar Streel • Everett, WA 98201 •(206) 259-8800 • Fax (206) 259-8856 �+ <br />
The URL can be used to link to this page
Your browser does not support the video tag.