My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7405 BEVERLY LN 2016-01-01 MF Import
>
Address Records
>
BEVERLY LN
>
7405
>
7405 BEVERLY LN 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2017 9:41:47 PM
Creation date
1/23/2017 2:23:20 PM
Metadata
Fields
Template:
Address Document
Street Name
BEVERLY LN
Street Number
7405
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Bob Champion <br />February 18, 1993 <br />Page 4 of 4 <br />33. A 1-HR fire-resistive occupancy separation is required hetween storage or laundry <br />rooms that are used in common by tenants and the rest of the building, Section <br />1202(b). <br />�4. <br />✓ 35 <br />Every sleeping room below the fourth story shall have at least one openable window <br />or exterior door conforming to Section 1204 for emergency escape or rescue, which <br />must open directly onto a public street or alley, yard or exit court. Please provide <br />window opening sizes for bay windows. <br />Provide smoke detectors in each sleeping room and in the comdor outside sleeping <br />areas per Section 1210. <br />36. Provide exha�ist fan sizes and whole house 'zn sizes per V.I.A.Q. Table 3-1 and 3-2. <br />All exhaust fa.�s must vent directly to the exterior of the building including the dryer <br />vents. <br />t�7. <br />l'38. <br />Indicate outdoor air inlets per V.I.A.Q. Code. <br />Provide insulation baffle� at eaves to ensure at[ic ventilation. <br />�39. Provide a section through ba�� windows indicating construction and floor insulation. <br />✓40. i�;di^ate all addenda items on drawings. <br />b%ll. Provide sheet A-1. <br />In order for !he processing of your application to continue, it will be necessary to provide the <br />Building Division with two complete new sets of drawings reflecting the cenections requested. <br />Upon resubmittal of the drawings, your application will be given priority and plan review <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure <br />that the �:roposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />i <br />� l <br />re . McFal <br />Associate Engineer/Building <br />JSM:cg/plsnckXS <br />
The URL can be used to link to this page
Your browser does not support the video tag.