Laserfiche WebLink
March 23, 2006 <br />Lcttcr tu Grcgg Capcs <br />Rf:: Plan Chcck No. COG03-043 <br />Pagc Z of 3 <br />9. Providc post at tlic enJ of Utc girdcr in thc crawl spacc. <br />10. 7'hc Floor in thc garagc shall hc slopcd to f:icili�atc thc movcment of liquids to a drain or <br />ilic main vchicic cntry dooneay. <br />Ll l�; "I�hc rool'on the garagc, on the IcR sidc, appcars to he a diffcrent pitch than thc rest of thc <br />roof. Picasc darify. <br />12. 'nc� mastcn c�droom is dra���n (not dimensioncd on plans) at 17' on thc Ooor plan, thc <br />clevation shows I S'. Plcasc clarity. <br />�"13. j Providc Jimcnsions fur all partitions. Show minimum width at corridors anJ landing at <br />— top of stairs. <br />�4jSpccity all finish matcrials on cicvations. <br />�5 Revisc elevations to reilect actual roof layoul per Itcm N2 above. <br />1 Ci. Show sizc and location of all attic ventilation on roof Gaming plan. <br />17. Thc door scparating thc garagc and thc dwclling sliould bc a solid wood core door, 1-3/8" <br />thick and tight-fi�ting, or a 20-minutc rated door. <br />I S. Providc minimum 50 cfm cxhaust fan in thc powJcr room. <br />12 Spccify safcry glass at hazardous locations, as detined by Scction R308.4 IRC. <br />20. Spccify cciling hcight in section vicws. <br />21. 'llic intcrior door to ihe g�rage should show a maximum 7-3/4" stcp to the first tread or <br />landing. <br />22. Providc guard, per Scction R312 IRC. Show rcyuircmcnts on plans. <br />23. Providc ���cathcr protection, such as �eatcqiroof Uuilding paper on cxtcrior walfs. Show <br />on plans. <br />24. Show mininttun (i' wond lo carth cicarancc on wood siding. <br />25. Concrcic supporting wood framing shall extcnd minimum G' abovc thc finishcd gradc. <br />Sho��� on plans. <br />2G. Pootings shall rest on undistunc�d soil not Icss than 18" bclow the finished grade. Show <br />on plans. <br />27. I'loor joists shuuld bc at Icast I S" abovc thc undcr Floor grndc. <br />2ii. UnJcr iloor girdcrs should bc slio«�n at Icast 12" abovc gradc. <br />''q. Pro��ide minimum 18"x24" cra«�I spacc uccess. <br />?0. Spccify all wond platcs and sills on concretc which is in contact with thc carth — should <br />uc pressurc trcatcd. <br />3 I. All extcrior columns, bcams mid joists that are exposcd to the wcathcr shall bc pressure <br />trcatcd. <br />ti:'JI.inJ.ny�AVURU',IIIiII.A1AN. 1APlun chcck Nu. COGU3-1143.UOC <br />�I3 <br />