Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br />j 4. Connecl s:e sewer per Ciry Standard #G01. <br />5. Connect :�e sewer per Cily Standard #'s 601, 6J2, 604. <br />6. Connect ali roo(lop downspouts to the side sewer. <br />7 Connect rooftop downspouls lo the drainage system provided for this lot. <br />ft. Rooflop runoff must bc discharged to a roof downspout infillratien system per City of Everett Storm <br />Manual 3-2.62. The approximal.. size irench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />9 The conhaclor must meet with �ne Public Works Inspector to discuss polential drainage routing prior to <br />beginninc� the project. <br />t0. Install erosion control measures as determined by the Public Works inspector, such as silt (ence, strarv <br />bales, swales, or erosion blankets. <br />Install erosion control measures per City of Evcrod Standards for small parcels <br />Remove erosion conlrol measures upon com�letion o( the projecl prior to final approval of the permit <br />All exc�:vafed mc;crial (rom (oundation, ,idewalk and dnveways shall be hauled to an approved, <br />pcimilted sitc_ No w,�sting o( malerial is allownd on �his building lo'. <br />No dirt, nwd, roc4s or d�bns to bc �rached untn ro,�dway- <br />No building materials �o be stacked on sicew�alks and sidewalks to be hept clean and open for <br />pedestrian travel. <br />Adust waler meter box 1" above sidewalk gradc <br />Remove and replace curb, c�ut�er and sidewalk as per Cily ol Everott Standard Plan #'s 305A 8 306 on <br />ihis proposal's (ronlage as direcled by lhe Public Works Inspector (i.e. all unused dri��ev.ays and any <br />brokc» or damac�ed area must be replaced). <br />Install a Type I concre�e driveway per Cily of Everell Slandard #3C7. <br />Pave driveway from the front properlv line out W lhe street paving. <br />20. Contact lhe _ <br />sewer services. <br />21 <br />22. <br />Waler Dislrict (or connecting provisions (or lhis building's water and <br />A catch basin as per Cily Slandard Plan #402 with a gas trap per Standard Plan #410 is required for lhe <br />parking area. <br />I( a sewer pump system is to be inslalled, th� pressure line must discharge into a private manhole, then <br />c�raviry (low across lhe public right-o(-way. <br />A sprinkler system is required for this building in compliance with the requirements of NFDA Standards <br />1.iD. <br />