My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1030 BROADWAY 2018-01-02 MF Import
>
Address Records
>
BROADWAY
>
1030
>
1030 BROADWAY 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2022 2:05:21 PM
Creation date
1/23/2017 6:37:43 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
1030
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
285
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • � ' . ' � I 0 �'�� �L�t ., . . . . <br /> � • � ' � �1 <br /> I 42, A Onc'Hour FirrHesis[ivc Otcupancy Separation j G4. Evcry slcepin� room bctow ihc fourth 11oor <br /> IS ffq�ircd briwCen lhC boiler o� [CnUel hC.tF Sho�ld h�vC al le.st one window or eztcrior <br /> inE P��nt and the resl of the buildm�. Seclion door approced for emer�mcy exd or rescue. <br /> � 808. .' Section ]304.�,�,,,,�G ��p�.i`C` <br /> � Grou D G5. ........................................................ room sl�ould <br /> , P havc Ihc minimum cciling hcight rcqui�cd in <br /> 49. froup I�, Uivi;ion 1 Otcup�ncics .hould bc ol Seetion 1307 (a). <br /> Typc 1 or II conslruclion un�rss compiyinp vrilh 66. ................................ . room should <br /> ihc Gception in Scction 902 (b). _ <br /> . havc a minimum superlicial floor arca of <br /> �D. Group D. Division 2 (3) Occupancics shouid 6e <br /> - '- .................... square fect. Setl�on 1307 (b). <br /> of onrhour firo-resistivc construtlion. Tablc g7, Etficicncy dwclling� units should comply wilh . <br /> No. 5�C. Section 1308. <br /> 5l. Lighl and venlilation should comply vri[h Seclion G8. A OnrHour Firo-Resislive Otcunanty Srpr�ratim� <br /> • 905. is requimd 6etwcen a boiler rcom cr eentral <br /> hcating planl and thc rest of the builJinG• <br /> .�,2. A One�llour Fire�Resislive Occupancy Separation $eclion 7312. � <br /> is rcpuircd L•etv:cen the boiler er central heat• � - <br /> inC pfant anA thc resl of ihc bwlding. Sedion G9. [vcry dwcllinF: uni• and gucst room shoulA havc <br /> 908. � � comfort hcating iacilitics as specified in Sec• <br /> - tion 1317. <br /> 53. [zlerior openings for rooms tontainine a boiler . <br /> or eenlral healing plant should Le pmtected • GroupJ <br /> with thrcedourths�hour fircacsistivc assembties <br /> ihal arc fized, automiti[, or self�closing il <br /> � lotated belo�v openin�s in another story or if 70. Group J Division I Otcupaneies are limited lo <br /> less ihan ]0 fcet fiom olhcr doors or windows 7000 (3000) squarc feet in floor arca end one <br /> � in the same buitding. Seclion 908. sLory in heighL Sedion 1502. <br /> � � Group F . � . 71. GaraEes ,houid not open dlreclty into a ioom <br /> . � used,for slcepin� purposes..Settion 150-0. <br /> 5:. Llotor vehide service sWtions shuuld be of nom 7p, An apProved noncombustible ma:erial or asphal- <br /> eombuseiblc firaretzrdant ucated v:ood or one• � �(� pavin� matcrizl is required for C�raGe fioor <br /> � hour fire�resistive construclion. Section 1102 ' sudaces. Section 1504. <br /> (b). .......................................................................... <br /> � • � .......................................................................... <br /> 55. SlorzEc �reas in ertess o( 100D square fcet in <br /> [onnectiomvrifh who!esale or idail ;ales �houid ��i RE UIREf�ENTS <br /> I�c separated from the public arcas by a Onc• � 4 ____ <br /> Hour firrHec��istive Ceeupancy Separallon un- <br /> l Icss ihe buildinG is equlpFed throuEhoul with 73. An occupanl load sign is required in ciassroums. <br /> •- an aulomaiic fim-extin�uishinG sYstem.Seetion assembly zrens, etc., having an occupanl load <br /> � � 1102 (b). ol mom than 50. Section "s301 (j). Scc ............ <br /> � 55. I Li�lit and ventiialion shoutd comply vrith Setlion ...._.._.............................................................. <br /> 1105. <br /> 74. Confomiing ezits are requircA irom fhc areas <br /> ' S7. Exliaust ventilalion at or near tloor Icvcl is rc• � bclorr as specitied in Section 3302 (a). <br /> � quircd by Section 1105.. ........."-............................................................. <br /> 5S. A OnaHour Fire�Resislive Ottupancy Separation � <br /> ..........._............................................................ <br /> ' is tequiicd between a boilcr room or central 7�, Ezits should have a minimum separation ot one- <br /> hcating piant and the resl of thc building. Sco haif lhc maaimum overall diagonal of the Luil�: <br /> � tion I108. ing or area served. Section 3302 (c). .............. . _ _.,...,+�:,, <br /> � , GroupH - � 7G. IJo poin[ in Ihc building should bc morc than � � <br /> 150 (200) fcet 1rom an er.ierior exi[, horizunial <br /> 59. A Group H Ocn�v-.ucy mcre than two sloties in exil, endosed stairvrey, or eait passagew.y, <br /> . hei�h[ or hz•.i:�g more than 3000 square tect mcasured in thc direction of trevel. Section <br /> � above thc first story sliould bc of one�hour � 3302 (d). .......................................................... <br /> • firo-resistivc construction throughouL Sedion �� ��t door shouid swin� in thc dircdion of � <br /> 1302 (b). eC�ess.Section 5303 (b). See doors ......_........� <br /> L.�. Thc foilowing rooms should have window arcas •••�-��•��-•��•���••�--•""""""""""" <br /> ' as specilied in Setlion ]305 (a), ore�half ot �p, poiible actin� doors are not allowed where scrv• <br /> . . whieh is openablc. � inp a lribulary occupanl load o(more than 100. <br /> . ................................._.................._.........._....... Seclion 3303 (b). <br /> ........"'_............................................................. � . <br /> "....................:................................................... )9. Ezit doors slioulcl be opena6le troin tlie insicie <br /> � Gl. Idechanical venlilalinG syslem in hathraoms wiUiout Ihe use of a key,spetial knowledge, or <br /> shoulJ pmvidc live .ir chanj;es per hour di• eilmL Sedion 3303 (c). Nulc also that Ilush <br /> � rectly lo the oulsida Sedion 1305 (a). bolls or sudace bolts are prohibiled. <br /> . i <br /> - • . G2. 11'indow,from .......................................... shoulA 60. Exil Aoors shnuld bc a mininami sizc of 3'z GII" <br /> � nol be eonsidemA as tun,�smn� reQwrcd ur.i�� Wi��� � �»inimum door swing ol 90 dcgrecs. <br /> � or venlilalion slnce Ihey do nol epen lo a yard. . Seetion 3303 (d). .............................................. <br /> murt, or sireet in accordaaee with Section <br /> � � 1305 (a). IIl. Thc net dimrnsion (dcar widUi) al doorv�ays <br /> � �� W'. Courts bounded on lour sides with walls slwuid shoulA bc used in dclr.rminin� exil vridihs <br /> bc at Icosl ]0 tccl imlenplh. Fo� rnurts moro requircd by tieclion 3i02 (b). -,edion 3303 <br /> Il�an hvo slories in hei�ht, the requireA v:idlh (d)• �o eonaderation of door Uiicknesse„ n�mc <br /> � shnuld bc incrcascd by onc loot and thc rr Imrdwarc, dnnr swinC� cic., Ihc wquired cxit <br /> quircd Icnglh hY L' Iccl 1or cach .dJilional widlhx liavc not bcen (umished. Sce door <br /> � � slory. Seclion 130G (e). .......................................................................... <br /> . . � ��....�_ .. _.. �,...._ . <br />
The URL can be used to link to this page
Your browser does not support the video tag.