Laserfiche WebLink
--------------------------------------------------� ---� . . . . . , <br /> . �' . <br /> HIGHLIGHTS AND CHANGES <br /> ! <br /> Building - <br /> * The fire resistive protection of columns and beams within <br /> assemblies requires individual protection unless tested as part of <br /> the assembly. <br /> � Susperded ceiling seismic brac3ng requirement is enforced. � <br /> � � Fire resistive asser�bly details are reGuired en plans (including + <br /> Test Number). ! <br /> * Stair sections are requlred showing rise, run and headroom. , <br /> (Stair run is not synonymous with tread and headroom is new a � <br /> minimum oP 6 feet 8 inches.) � <br /> • Secticns and details are to be related to the speciPic conditions - � <br /> "Typicals" are rot acceptable. � <br /> Plmb/Mech - <br /> � Floor drain prlmers are required. <br /> . * Gas piping is not to be concealetl unless access panels are provided. <br /> " Roof access (permanent) is required Por mechan.t�al equipment, <br /> R Oryer vent maximum length is 14 feet with two•90° elGows. <br /> " Sheet metal screws are required at the ,joints oP prefabricated <br /> metal chimneys. <br /> * Barrier free water closet height 3s 17 to 19 inches. <br /> * Laundry rooms (including closets) require s fan. <br /> Electrical - <br /> �= �� " Wiring in non dwellings is required to be in conduit. . <br /> State electrical plans review is required for educatioral, <br /> institutional and health or persanal care occupanci.es prior to <br /> permit issuance. <br /> 5378H <br /> '`�7/J./89:'`,;�: <br /> 2 _ � _ ..��5 <br /> \V G ����- <br /> ��� �-� ,,,���.� c,� <br /> ��. v `� �,W <br /> �. <br /> -�•� roo-� i.�Nnr•a Fr•SL �P �=Q bSSL9�5 :Ol 1d34 �JNIQ�IfIH 113?J3f13:W0ad <br />