Laserfiche WebLink
. � 1 <br /> ' . . ._ . • . • " <br /> . �j�, /���-L���.,�,.> <br /> / <br /> 82.` A floor or landing not morc than i inch below 303: ERterior stairS should not project into an area <br /> the threshol0 is required on each side of an (yards or courts) where wall openings must be <br /> exit door. Seclion 3303 (h). � proiected. Section 3305 (m). <br /> � 83.� Doors sh�uld not project more tlian 7 inches in� ]04: One stairway shoulA extend to the roof. Section <br /> to the required corridor widlh when tully 3305 (n).It must be in a smokeprool enclosure <br /> opened or more than onrhalt into the required in buildings over 75 leet in height. Section <br /> rorridor widW when in any position. Section 3309 (L). <br /> 3304 (d). .......................................................... 105.` Six�foot 6�inch minimum headroom clearance tor <br /> 84.' Revolving(sliAing) (overhead) doors are not per- stairways should be indicated on pians.Sedion <br /> mitled as exit doors. Srction 3303 (t). 3305 (o). Note that this is irom a plane tan- <br /> gent to lhe s:airway tread nosin�s. <br /> 85.' Ezit doors should proviac immediate atcess to <br /> an apProved means ot ef:ress. Sedion 3303 106: Ramp slopes should not ezceed onc toot in <br /> (g). Eziling throu�h anothei room does not ................................feet. Section 3306 (c) (d). <br /> compiy. <br /> 86.� Corritlors slioutd have a minimum width of 44 307.� Surtace of ramps shoutd be roughened or of a <br /> inches. Seclion 3304 (b). nonstip materiai. Section 330G (t). <br /> SZ�� Conidors serving nonambidatory persons should 308.� Stairways should be endosed as sDetified in <br /> have an S�foot minimurn width. Section 3318 Section 3308. <br /> ��� (a) Onc (two)-hour tire-resistive walls are re• <br /> quired. <br /> 88.� DeaA end of corridors and exit balconies are (b) Only exit doors are allowed to open into ezit <br /> limited ro 20 teeL 9ection 3304 (i). enctosures. . <br /> (c) Doors should be la6eted one (one�and�one• <br /> 89. Walis anA ccilings of mrridors should be of onN haif)�hour fire assembiies. <br /> . hour fire-resistive consiruction. SeMion 3304 (d) Exit enclosures should inclvde a corridor on <br /> • -_ (�). An architectural section through ihe corri• the Gmund 11oor extending to the ezterior. <br /> dor is necessary to determine how this is Firrresistive construction should be as re- <br /> accomp�ished. quireA for the exit enclosure, includinR pro� <br /> 90. Ealerior exit baimnies wnnot ro'ect into an tecled openings. Only exit doors are per• <br /> P 1 milled to open into the corridor. <br /> ama where protected openings arc required (e) An approved barrier is requimd at ihe <br /> due to location on property. Section 3304 (i). ground Iioor to prevent people irom acci- <br /> ..................-.....-................-.............................. dentally continuing to the lower Ievei. <br /> 91. Interior openings into rorridors should be pro- (f) Usahlc space is not allowed under lhe <br /> �. tecled as epecified in Section 3304 (h). stairs. � <br /> .............................................................................. <br /> . 92.� Stairway .._............_...................._.. shoWd have <br /> a minimum width of ...............__. inches. Trim 109: Onc ezit from lhe building should Ge a smoke• <br /> and handrails should not project mom fhan proof enclosure compiyinr; with Section 3309. <br /> 3�/� inches into the required width. Section <br /> 3305 (b). I10: Openings inlo exit courts Iess than 70 feet viide <br /> 93."�Riscrs on stairwa s should not exceed 7�/z shoWd be protecteJ with labeled 45�minute fire <br /> Y assemblies. Section 3310 (d). Also see "exit <br /> inches and runs should nol be less ihan 10 court" detinition in Section 3301 (c). Openin�s ' <br /> inches. Section 3305 (c). more than 10 feet above 1he court tloor are <br /> 94.� Lantlings on stairways should have a dimension exempL � <br /> in the diredion o( travei equal to the width of ��7; No openings other than required exits are per- <br /> the stairway bul need not ezceed 4 teet. Sec• mifled in c*it passageways. The passagev;ays <br /> tion 3305 (f). shoutd be oi............._...._... •hour fire�resistive <br /> 95. Landin�s should not be teJuced in width more constmclion. Sec:ion 3311 (a). <br /> than 3�/� inches by a door when fully open. �32.` Exit illumination and signs should be pmvided in <br /> Section 3305 (f). coMormance with Sedion 3312. <br /> 9G. Qasemert pnriion nf staitways should have an 113. Aisle (cross aisie) in auditorium shouid have a <br /> approved barrier w.hero continuous to upper minimum wiJ�h of _.._...... ................... Section <br /> 1loors in an ezit enclosure. Section 3305 (�). 3313 (b). Scction 3313 (e). • <br /> ' 97.�I Verlical Jistnnces bet�5�ren stairway landings are 114: Panic hardwere is reQuireA vn exit doors serv'�C • <br /> limited to 12 iceL Seclion 3l05 (h). <br /> Group [3 Otcupancir.s having an nccupant load <br /> . 98.� Handreils should be placed not Icss than 30 of more than ]00. Section 3316 (a). In lieu <br /> inches nor more than 34 inN�es above the of this, Aoors shall have no locks or latches. <br /> trcad. Seclion 3305 (i). Two handrails are ra• - � <br /> quimA where slairways exceed 4M1 inches in .15. Main andrside exits in contormance Milh S_c- <br /> width. tion 331�are required tor f3�2 (1)Ocr,upancies. <br /> - Sectinn 3316 (a). <br /> 99."�Guardrails for slairs, balronics, and landings - " � <br /> � should confoim wilh Se-lion 1714. Note that I1G.' Corridors oi Group C Occupancies s hould have a <br /> mazinunn clearance 6Mw�een intennediate rails widfh mquired by Seclion 3302 phis 2 leel, but <br /> is 9 in[hes. N��c.H'j r�n-'. 41•' , not less fhan G feeL Section 33ll (e). <br /> 100.'� Opm�in�e�, in ezlerior vmlls wi:hin 10 tect ot 117•' Cach floof atwvc or bclow Lhe ground 11oof levcl <br /> � ezlerior staiiways should be protected wilh of Group C Occupancies should liave no less <br /> � sclLdosinp three�fowths�hour fire�resislive as� tlian 1wo exit stairs. Section 3317 (G). <br /> . sentblies, tiecfion 3305 (k). �78,'I Cxit stairs servin� an occupant iond of more <br /> ]Ol. EndoscA usnblc space undcr intcrior stairway; ihan ]00 in a Group C Occupancy should havn, <br /> should bc prolcded on tl�c encloseJ sidc as a minimum dcar wiAlh of 5 icM. Section 3317 , <br /> rcyuired 1or onr�liour tirrresistivc construc ��)• <br /> tion. ticciion 3305 (I). . <br /> 119. Lvery room with an occupant load exceeAing <br /> ]02.' Noncombwliblc extcrior slairs are required. 30�should havc onc of iL^ er.its inlo a separate <br /> Secllon 33U5 (m). exit system. Seclion 3317 (6). <br />