Chapter 6.Plumbing Elements end Facilities � �J 1 ICC/ANSI A177.1-2003 <br /> 2. In a Type B unit,when a side wall is not � /�M a , 36 min <br /> available for a 42-inch (1065 mm) grab `�l.L 915 �2 min <br /> bar, the sidewall grab bar shall be per- 305 <br /> mitted to be 18 inches (455 mm) mini- 24 min <br /> mum in length, located 12 inches (30 610 <br /> mm) maximum irom the rear wall a d r� <br /> extending 30 inches (760 mm) ini- <br /> mum irom the rear wall. <br /> � <br /> a I <br /> 39-41 �o � o <br /> � rn � <br /> 990- 1040 c � � c — <br /> 54 min m � � � �� <br /> 12 ma�c 1370 "' °' � <br /> � <br /> 305 <br /> 42 min <br /> i 1065 FIg.604.5.2 <br /> Rear Wall Grab Bar for Water Closet <br /> Section 609.4\ � <br /> � �n a � <br /> � �, i i 604.5.3 Swing•up Grab Bars.Where swing-up <br /> i i � o grab bars are instaUed,a clearence of 18 inches <br /> � m m (455 mm) minimum irom the centerline of the <br /> water cioset to any side wali or obstruction shall <br /> _ be provided. A swmg-up grab bar shall be <br /> installed with the centerline of the grab bar 153/q <br /> Fig.6oa.5.t inches (400 mm) from the centerline of the wa- <br /> Side Wall Grab Bar tor Water Clo�et ter closet. Swing•up grab bars shall be 28 inch- <br /> es(710 mm)minimum in length,measured from <br /> the wall to the end of the horizontal portion of the <br /> 604.5.2 Rear VVall Grab Bars. The rear wall 9�ab bar. <br /> grab bar shali be 36 inches (915 mm) minimum 153�4 <br /> in length, a�d extend from the centerline of the <br /> water dese; 12 inches (305 mm) minimum on 400 �e <br /> the side closest to the wall, and 24 inches (610 '� <br /> mm) minimum on the transier side. <br /> EXCEPTIONS: �� I <br /> 1. The rear grab bar shali be permitted to O I I <br /> be 24 inches (610 mm) minimum in II <br /> length, centered on the water closet, II = <br /> wherewallspacedoesnotpermitagrab II E o <br /> bar 36 inches (915 mm) minimum in II N � <br /> length due to the location of a recessed I I <br /> fixture adjacent to the weter closet. � <br /> 2. In a Type A or Type B unit,the rear grab � <br /> bar shall be permitted to be 24 inches <br /> (610 mm) minimum in length, centered 18 min te min <br /> on the water closet, where wall space 455 455 <br /> does not permit a greb bar 36 inches - <br /> (915 mm) minimum in length. Flg.604.5.3 <br /> 3. Where an administrative authority re- Swing-up Grab Bar for Water Closet <br /> quires ilush controls for flush valves to <br /> be located in e position that contlicts <br /> with the location of the rear grab bar, 604.6 Fiush Controls.Flush controls shali be ha�d <br /> that grab bar shall be permitted lo be operated or automatic. Hand operated flush con- <br /> splitorshiftedtotheopensideofihetoi- trols shall compiy with Section 309. Fiush controls <br /> let area. shall be located on the open side of the water closet. <br /> BC6d 7-Da.S <br /> 48 <br />