Laserfiche WebLink
GHAV <br /> P� � �� CIVIL ENGINEERINC.,LAND PL4NNING,SUMEVING.ENVIRONMENTAL SEiNICES I <br /> m `. Z nusu�c �o, �v�s <br /> � . <br /> -,' � <br /> �y��,�� ° ���0 bl� <br /> Tim T ler, Buildin Official � <br /> Ciry of Everett � AU� I 1 � � <br /> Building Division 998 <br /> ........... . <br /> 3200 Cedar Street CIT � <br /> Everett, WA 98201 Enp;��serinp/pub��Es ryT se <br /> RE: Proposed ARCO AM/PM Facility-Plan (:heck No. B57726 <br /> 1806 Broadway Avenue, Everett, Washington <br /> Our Job No. 6108 <br /> Dear Tim: <br /> According to the plan check mark ups on Sheet A2-2, of the Permit submittal drawings, there is a requirement <br /> f'or a 30-inch parapet above the roof deck alonn,the west wall at the AM/PM building. We have reviewed this <br /> and determined that a 30-inch pnrapet is not required by thc Uniform Building Code based on the following: <br /> 1. The propeny abuts a 24-foot-wide alley along the west side. <br /> 2. Per Section 503.1 (attached), the centerline of an adjoining public way shall be considered an <br /> adjacent property line. <br /> 3. Per Table 5-A(attached), for type V-N Construction of M occupancies, bearing walls shall bc <br /> of one-hour conswction and openings shall be protected if less than 10 feet from property line. <br /> 4. Per Section 709.4.1 (atWched), parapets need not be provided on exterior walls. When due <br /> [o the location of the property line, the wall may have unprotected openings. <br /> We are currently pmparing the construction release drawings and we will keep the parapet at the present <br /> height of 1G inches t above the roof. <br /> The second mark-up on Sheet A2-2 calls for perimeter footing insulation. Attached is a copy of an April 29, <br /> 1998, letter from Colleen Haulrigs, of Barghausen Consulting Engineers, inc. The revised energy <br /> calculations demunstrate that footing insulation is not required;therefore, the construction release drawings <br /> will not include perimerer insulation. <br /> Please teel free to contact me if you have any questions or comments concerning the abovc informatien. <br /> Res ct ly, <br /> Dou las G. Pedersen, R.A. <br /> Project Architect <br /> DGP/edph �G108c.017] <br /> enc: As Noted <br /> cc: Bob Singh <br /> Jay S. Grubb, Barghausen Consulting Lngineers, Inc. <br />' Daniel D. Goalwin, IIarghausen Consulting Engineers, Inc. <br />�t' F. Al Kendall, Barghausen Consulting Engineers, Inc. <br /> 18215 72ND AVENUE SOUTH KENT,VJA 98032 (425)251-6222 (425)251-8782 FAX <br />