Laserfiche WebLink
� �, <br /> CITY OF EVERETT <br /> BUILDING DEPARTMENT <br /> PLAN CORRECTION SHEET <br /> DATE Aoril 14. 1986 USE <br /> 019NER John Martinis sr. USE ZONING <br /> CONTRACTOR xurt F. Stahl Construction FIRE ZONE <br /> DESIGNIIt _ OCCUPANCY GROUP I <br /> JOB SITE ADDRESS 1913 Broadway OCCUPANT LOAD I <br /> TYPE OF CONSTRUC'TION PLAN CHECK N0. 85/163z9 <br /> In response to your application for a permit, your plans and specifications <br /> have been examined and you are advised that the issuance of a permit is <br /> withheld for the reasons hereinafter set forth. NOTE CAREFULLY: Answer <br /> qt�estions and make explanations by correctinR original plans , and new <br /> r..lans must be submitted to the Building Inspection Department . (This sheet <br /> must be returned with original plans and specifications or they will be <br /> filed as new business . ) <br /> Item No. UNIFOR��S BUILDING CODE 1982 EDITTON CODE SEC. <br /> 1. Submit detail of how trusses will be supported. <br /> 2. Concealed space above insulation must be ventilated. Net 3205(c) <br /> free area = 9.2 square feet required. <br /> 3. Edge insulation of R 9.25 is required under floor slab - State Energy Code <br /> 24" wide. <br /> 4. Parapet walls are required to be 2' , 6" high. 1709(a) <br /> 5. Submit detail of rnar roof overhang. <br /> 6. Horizontal bond beams are required at 48" o.c. with 2 - #4 2417(j) <br /> bars each. <br /> 7. Concrete block walls must be insulated to R-11. State Energy Code <br /> 8. Dowel new concrete and �asonry to exis*.ing. <br /> � <br /> v <br /> " A, u . Y ! <br /> ack E. Frets � <br /> lans Examiner } <br /> E <br /> i <br /> 1 <br /> i <br /> � <br /> Page i of i ' <br /> . <br />