My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3231 BROADWAY 2018-01-02 MF Import
>
Address Records
>
BROADWAY
>
3231
>
3231 BROADWAY 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 2:44:48 PM
Creation date
1/24/2017 4:53:58 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3231
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
303
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i , <br /> . April 27, 1971 <br /> cri oc <br /> � everett <br /> � Pepsi Cola B�.•ttling Oo. <br /> I CITY N1LL � 3!s.�.'v.` <br /> 3231 B'.:oadway �:�acn. �.s- .:•-��. <br /> I Evere[`t, Washin;ton 98201 �-� <br /> :'.SFECTI04 _i��c•�.E".i <br /> Re: New IIuilding, 1118 SOth Placc, Everett, Washington / <br /> Gentlemen: <br /> The following requirements of the Uniform tluilding Code nust be met <br /> br.fore a building permit is to be issued for the balance of the <br /> .:onstruction. <br /> i� 1. Justi:y [he total cost of thc building. <br /> 2, Provide solid core door wi[h self closer to workshop area. <br /> SecCion 503 and Tablc 5 13. „ <br /> 3. (;hange s•.ing of door [o liquid and sugar concentrate area to <br /> swing in ?ine of egress, or change to double acting doors <br /> � wi:h 200 square inches uf view panel in each door. Sec. 3303 (b) . <br /> ' 4. Pro[ect columns in area separation wall with 2-hour protection. <br /> I 505 (c) . Threc layers of 5/S" X rated gypsuii required. (Table <br /> � 43 �1, item 25) ' <br /> � 5. Area separation wall =ha11 bc two-hours (two laycrs of 5/8" X <br /> rated gypsum board each side) with 1� hour openings. Sec. 505 (c) <br /> 6. Door openings require B-label doors, frames and hardware, sclf- <br /> closing with fusible links. Sec. 4306 (b) and (e) (lOG Sq. In. <br /> of wire glass each door) Windows not allowed in 2-hour wall. <br /> 7. Toilet rooms shall have hard, smooth, non-absorbent floors and <br /> 4'0" high wainscot. Sec. 1711 (a) <br /> 8. Submit Technical information regarding plastics, and conform to <br /> Chapter 52. <br /> 9, Provide exhaust system for garage area. Sec. 1105 <br /> � 10. Provide wet stand pipes. Section 3804 <br /> 11. Provide fire curtains in space betwcen floor and suspended <br /> ceil'dings 1000 sq. feet masirium. ;ec. 2517 (e) <br /> 12. Change detail of second floor fran�:ng into 2-hour wall for 2•hour <br /> protection. <br /> 13. Provide 2-hour wall to roof at wall between vending service and <br /> ' bottling area. <br /> 14. Storage room live loads shall comply with Table 23 A. <br /> 15. Drawings do no� agree with specifications regarding Sec. 2314. <br /> 16. Provide lateral support for masonry walls in eccord with 2419 (b) 2, <br /> 2417 (c) and Table 7.4 I. <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.