My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3417 BROADWAY 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
3417
>
3417 BROADWAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2017 5:46:41 AM
Creation date
1/24/2017 5:45:20 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3417
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' �N�r s 3 o Z �, 303 � 2001 EDITION <br /> C1z'��) � <br /> TABLE 6•1 <br /> PRESCRIPTIVE REOUIREMENTS01 FOR GROUP R OCCUPANCY <br /> � CIIMATE 20NE 1 <br /> Glazin� Glazin U-Factor Wall Wall. Wal�. Slab' <br /> Option ArcB' . Ooor 9 Ceiling� Vaulted Above �^� �� Floors on <br /> %of Floor Vertical Overhead" U�Factor Ceilin8 GraOe'� Below Below Grsde <br /> Grade Grede <br /> —� I. 12°io 0.35 0.58 0.20 R-38 R•30 RIS R-IS R-10 R•l0 R-10 <br /> 11.• IS% 0.40 0.58 0.20 R•3R R-30 R-21 R•21 R-10 R-30 R-10 <br /> III. UnlimitW 0.40 I 0.58 0.20 R-38 R-30 R-21 R-21 R•10 R-30 R-10 <br /> Group R-3 <br /> Occupxncy <br /> OnI � <br /> � <br /> * Reference Casc <br /> 0. Nominal R-values are for wood frame assemblics only or asscmblies built in accordance with Section 601.1. <br /> l. Minimum rcquirements for each opiion lisied. Por example, if a propesed design has a glazing ratio�o thc con6irSoned floor <br /> area of I 3%, it shall comply with all of the requiremcnts of the 15%glazing option (or higher). Proposed designs which cannot <br /> mtet ihe specific requiremrnts of a listed option abeve may calculate compliance by Chapters 4 or 5 of this Code. <br /> 2. Requiremem applies to all ceilings except single raRer orjoist vaulted ccilings. 'Adv'denotes Advanced Fr�med Ceiling. <br /> 3. Requirement applicable only to single rafter orjoist vaulled ceilings. <br /> 4. Delow grade walls shall be insulated cither on the cxterior to a minimum levcl of R-10,or on thc intcri��r to the same level as <br /> walls above grade. F,xterior insulatinn installed on bclow gradc walls shell be a water rr,sistant material,nianufactured for its <br /> intended use, and instailcd according to the manufacturer's specifications. See Section 602.2. <br /> 5. Ploors ovcr crawl spaces or exposed to ambient air conditions. <br /> 6. Requircd slab perimetcr insulation shall be a watcr resistant matcria(, manufar,turcd for its intended usc,and installcd <br /> according 10 manufacturer's spccifications. See Section 6G2.4. <br /> 7. Int. denotcs standard (raming 16 inchr,s on center w ith hcaders insulatcd�ti�th a minimum of R•5 insulation. <br /> 8. This wall insulation requircment denotes R-19 wall caviry insulation pb�s R-S foam sheathing. <br /> 9. Doors, including all fire doors,shall be assigned default U-factors fro�n Table 10-5C. <br /> 10. Where a maximum glazing area is listed, the total glazing area(combined vertical plus overbead)as a percent of grou <br /> conditioned tloor area shall be Icss ihan or equal to that valuc. Ovenc�ad glazing with iJ-fac,er of U=0.40 or less is not included <br /> in glazing erce limitations. <br /> 1 I. Overhead glazing shall have U-factors detertnined in�ccordance•hith hFRC 100 or as specificd in Section 502.1.5. <br /> 12. I.og and solid timber w�lls with a minimum average thickncss of 3.5" are excmpt from this insulelion requiremrni. <br /> /y <br /> Eflectwe 7/01/02 33 <br />
The URL can be used to link to this page
Your browser does not support the video tag.