nov. OS 2002 10: 08HM HP LRSERJET 3200 P• � I <br /> i <br /> �i.E1vN C wEI.I.S�� �A � <br /> ARCHITEf� T <br /> i <br /> xa��t�z,zoo2 <br /> Steve Miller <br /> City of Evereu <br /> 3200 Cedar Stcee! <br /> Everett WA 98201 I <br /> RE: Whitfield's Mixed-use Building � <br /> Dear Steve: <br /> Th�foilowing letta will serve as my response to your plan chect letter dated 3eptember]2,2002. <br /> Ium i: The existing Uuilding will be sprinklerod. <br /> the ms and the offices <br /> bl will fx ovided txtweea , <br /> Item 2:A one-kwur fluor assem y pr apart�n� <br /> and one how walls betw�een We apa�meMs par UBC Sections 302.3 and 310.2.2.All beams <br /> and column connections within the floor/ceiGng essembly will elso be proxcud TI►e fire <br /> sprinkler system required per ordinance will be sub�tidrted for die one-hour columns and <br /> walls suppoRing the floor/ceilieg as.cembly required in UBC section 302.2.The drawings <br /> have been modified to reflcet this change. <br /> Item 3: The south wall nf d�e sou!h aputment is ono-hour. This wall p�ovidos tbe required <br /> seperadon. The north wall of the upsteirs office is eot rated,na is the door inW thie oPfice. <br /> Item 4: The basement floor has nccess to the saoond floor restrooms in the existing building, <br /> thus addiHonal restmoms are not naeded. <br /> � <br /> If you t�ve any quesrions conceming this matter,ploese do tmt hesitate to call. ' <br /> Yours very Uuly, <br /> �`� <br /> Glenn C Wells <br /> Principal <br /> — <br /> 1235 Founh Avmne E,Ol}�mpia ♦ I? 0.Box 3016,Lacey VVA 98309 • P6w� (]60)352-4553 ♦ Fi�X: (360)352-2044 <br />