Laserfiche WebLink
2007 VJashington State NonresiCential Energy Code Compliance Fortn <br /> � • <br /> , i � � . ; . <br /> �JOt\Yas^��g:aa S:am Nr.rnesmr�ua'Encryy Co�n Cor,piu�ra�vms Frsl H^.�.m J no?0^t <br /> PfOJC'CIA:1CfC55 �t�EP.EiT Gr:EeAY CEN:EP., AETAIL ELJG. 3 Date 10/7/2005 <br /> Space Heat Type `�EleUric rosistance • All other Fcr Build�ng Depanment Use <br /> C,idZi❑ AreB as°/gross exterior wan area 27•ib Prop. 40.O+k �+1ax.Target <br /> Concrete/Masonry Option C-�v�s �.: No <br /> Notes:II giazing area exceeds maz�mum allowed in Table,then ca culate adjusted areas on back(over). il Concrete%Masonry Option <br /> is used,Target U-lacto�s,SHGC antl Glazing°/will be diHerenl lhan shown below. Refer to Table 7?-1 for correct values. <br /> Building Compunonl Proposed UA Target UA <br /> List componenls b assembl ID 8 page# U-factor x Area(A1 =UA(U x A1 U-lactor x Area(A) =UA N x A) <br /> U=0.400 FIanlD:wi�eo. [ypee A6.1 0.400 1443.7 577.5 0.900 1443.7 577.5 <br /> U= Plan ID: Glazing% Electric Resist. Other Heating <br /> U= Plan ID: 0-15% OAO 0.90 <br /> � � >15-20% 0.40 0.75 <br /> _ � U= Plan ID: <br /> > c7 U= Plan ID: >20-30%a nol all�wed 0.60 <br /> U= Plan ID: >30-40°/ not allowed 0.50 <br /> U= Plan ID: (see Table 13•7 for ConGMasonry values) <br /> � U= Plan ID: <br /> m Q U= Plan ID: Glazing°/ Electric Resist. Other Heating <br /> �� w U= Plan ID: 0-15`/0 0.80 1.45 <br /> > <br /> � � U= Pian ID' >15-20'/ 0.80 1.40 <br /> 'a' � U= Plan ID: >20-30% not aliowed 1.30 <br /> u <br /> L °o U= Plan ID: >30-00% nol allowed 125 <br /> O � U= Plan ID: (see Table 1° +for ConclMasonry values) <br /> � U= Plan�D: <br /> m y U��0.600 P13nID:echadule Afi.l 0.600 168.0 300.8 0.60 168.0 300.8 <br /> � g U= Plan ID: Eleclric Resist. Other Healing <br /> O� U= Plan ID: � 0.80 0.60 <br /> � � R= PIanID: o.o3c <br /> 3 > r R= Plan ID: Electric Resist Other Hea6�g <br /> e � ' R= Plan ID: 0.031 0.036 <br /> � N R=71.0 PIaf1lU:ebeate Ae.i, ae.3 0.090 5597.0 266.' 0.050 5597.0 279.9 <br /> _ o R= Plan ID: Electric Resist. Olher Heat�ng <br /> � � R= Plan ID: 0.034 0.050 <br /> R=19.0 PIanlD:snaeca A5.1, A5.2 0.100 3711.0 371.1 0.19 3711.0 519.5 <br /> R= Plan ID: <br /> '" R= Plan ID: <br /> 3 R= Plan ID: Eiectric Resist. Olher Healing <br /> Q R= Ptan ID: Ordinary 0.062 0.14 <br /> n R= Plan ID: Conc(int) 0.79 0.19 <br /> � R= Plan ID: Conc(oth) 0.25 0.25 <br /> "Note:sum of Target Amas here should equal Target Opaque Wall Area lsee back) <br /> R= Plan ID: <br /> � a ° R= Plan ID: Electric Resist. Other Hcating <br /> o � z R= Plan ID: 0.062 0.14 <br /> Note:if�nsulated to Ievels required(or opaque walls,list above with ooaque walls <br /> � , R= Plan ID: <br /> ) � R= Plan ID: Elearic ResisL Cther Heating <br /> " � u` 0.029 0.056 <br /> 3 � R- Plan I�: <br /> � R= Plan ID: <br /> ' � � R=0 PIOnID: OJ30 0.590 <br /> � � � R= Plan ID: Elechic Resisl. Olher Heating <br /> � �a R= Plan ID: F=D.54 F=0.54 <br />� R= Plan ID: (se^Table 73-i for radianl lloor values) <br /> 'For CMU walls,indicate core insu�alion material. Totals 19919.7 1315.9 Totais 10919.7 1477.7 <br /> For compliance: <br /> i)Proposed Total Area shall equal Targe, �o a rrea,dna[ ropuse o ai A shall no eacee arge o . <br /> �7 � <br /> ���� , <br />