My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3732 BROADWAY 2018-01-02 MF Import
>
Address Records
>
BROADWAY
>
3732
>
3732 BROADWAY 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2022 4:05:44 PM
Creation date
1/24/2017 7:59:14 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3732
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2007 VJashington Slate Nonresidential Energy Code Compliance Form <br /> • • • • <br /> Pb?11Yny�ington S�ala NonrexNenual Ene!BY�e�"".�"'^".n�O•-" Frst EC�ron.June 2001 <br /> Project Info P�ojectAddress E'JEFETT GFTE%A] fEN:ER, FE:A:L ELCB. 7 Date 1��1��Z�Q$ <br /> r�s eaour:xx For BuilCing Departmr.nl Use <br /> EVERE2i, NA R r a;�.�" (`� <br /> APpIiC0ntN3fnBl Corneretove Architeetur�l Czouy �:.J� lO I V�5 <br /> ApplicantAddress: lya� 3re r�en�a susce xsoc <br /> Applicanl Phone: �=os) se¢-s000 <br /> Project Description �New Buiiding ❑Addition �Alleration [J Change ol Use <br /> []Prescriplive L1 Component PeAormance ❑ ENVSTD 2.1 []Systems <br /> COIIl��1.111CC �V�l01t (SeeDecisionFlowchart(over)lorqualifcations) (4.Onotacceplable) Analysis <br /> SpdCe He�t TYpe (;E�ectric resistance i�;A��other (see over for OeGnitions) <br /> Tolal Glazing Area Eleclronic version: Uiese values are aulomatically taken from ENV-UH-1. <br /> Gla�ing Area Calculation (rough opening) Gross Exterior <br /> Nole:Belowgratlo wnll5 may be included in thu (�ertical&overhd) divided by Wall Area times 700 equals °/Glazing <br /> GmssE�tenorWallAreailthcyaminsulatedlo 1005.2 - 4470 .0 X ��� = 2Z • 5� <br /> Ihe lovel reqWretl for opapue walls. <br /> � yes Check hem il using this option ana fl proJod meets a0 requirements lor the Concrete:fdasonry <br /> COIlCYC�'C d5011 � t1011 Option. SeeDecisionFlowchart(over)lorquahlications. EnterrequimmenlsbreachpuaLying <br /> � � p ��� ^� assembty below. <br /> Envelope Requirements(enter vaiues as applicable) Opaque ConcrelelMasonry Wall Requirements <br /> Fully heated/cooledspaca Insulation on interior-maximum U-factor is 0.19 <br /> Minimum InsWc!inn R-values Insulation on exterior oi ir.tegral-maximum U-factor is 025 <br /> Roofs Over Altic If projecl qualifes for ConcretelMasonry Option,lisl walls <br /> All Olher Roofs g_y 1 with HC 2 9.0 Btu/fi'•`F below(other walls musi meet <br /> Opaque Wall requirements). Use dcscriptions and vaiues <br /> Opaque Walls' R-19 trom Table 20-Sb in_he Code. <br /> Below Grade Walls Wall Descriplion U•taclor <br /> floors Over Unconditioned Space (including insulation R-value 8 position) <br /> Slabson-Grade N/A <br /> Radianl Floors <br /> A1aximum U-/acfors <br /> Opaque Ooors U .6 <br /> Vertical Glazing U .4 <br /> Overhead Glazing <br /> Maximum SHGC(or SCj <br /> Vertical/Overhead Glazing <br /> Semf-heated space° <br /> � Mir.imum Insulation R-values <br /> � Roofs Over Semi-Heated Spaces� <br /> 1.Assemblies with metal Iraming musl comply�wth overall U-faclors <br /> 2.Refer to Seclion 13101or qualiGcations and requirements <br /> NOt@S: <br /> 1 � i <br /> J . <br />
The URL can be used to link to this page
Your browser does not support the video tag.