Laserfiche WebLink
CITY OF EVERETT STORMWATER MANACaEMENT MANUAL <br /> �} <br /> � 14. The tence posts shall be placed or driven a minimum of 18 inches. A minimum depth of <br /> 12 inches is allowed if tapsoil or other sofl subgrade soil is not present and a minimum deplh of <br /> 18 inches cannot be reached. Fence post dep�hs shall be increased by 6 inches if the fence is <br /> located on slopes of 3:1 or steeper and tLe slope is perpendiculu to the fence. If required post <br /> dept6s cannot be obtained,the posts shall be adequately sccured by bracing or guying to prevent <br /> overtuming of thc fence due to sediment loading. <br /> l5. Silt feoces shall be located on contour as much as possible,except at the ends of the fence,where <br /> the fence shall be tumed uphill such that the silt fence captures the runoff water and prevents <br /> water from tlowing around the end oFthe fence. <br /> 16. [f the fence must cross contours,with the excepdon of the ends of the fence,gravel check dams <br /> plaxd perpendicular to the back of thc fence shall be used to minimize concentrated flow and <br /> erosion along t6e back of the fence. The gravel check dems shall be approximately 1-foot deep at <br /> the back of the fence. It shall be continued perpeodiculaz to the fence at the same elevation until <br /> the top of the check dam intercepts the ground surface behind the fence. The gravel check dams <br /> shall consist of ccushed surfacing base course, gravel backfill for walls, or shoulder ballast. The <br /> gtavel check darns shall be located every 10 feet along lhe fence w6ere the fence must cross <br /> contours. The slope of the fence line wherc conrours must be crossed shall no1 be steeper than <br /> 3:1. <br /> 17. Wood,steel or equivalent posts shall be used. Wood posts shall have minimum dimensions of <br /> 2 inches by 2 inches by 3 feet minimum Icngth,and shall be free of defects such as Irnots, splits, <br /> or gouges. Steel posts s6all consist of either size No. 6 rr.nforcement bar or lazger,ASTM A 120 <br /> steel pipe with a minimum diamater of 1-inch,U,'f, L,or C shapc stecl posts with a minimum <br /> weight of 1.35 pounds/feet or other sleel posls having equivalent strength and bending resistancc <br /> � to the post sizes listed. The spacing of the support posts s6a11 be a maximum of 6 feet. <br /> i <br /> i 8. Fence back-up support,if used,shall consist of steel wirc with a m�imum mesh spacing of <br /> 2 inches,or a prefabricated polymeric mesh. The strength of the w've or polymeric mesh shell be <br /> equivalcnt to or greater than 180 pounds grab tensilc shength. The polymeric mesh must bc as <br /> resistant to ultraviolet rediation as the geotexeile it supports. <br /> 19. The base of both end posts must be at least 2 to 4 inches above the top of the silt fence Fabric on <br /> the middle posls for ditch checks lo drain properly. Use a hand level or string level,if neccssary, <br /> to mark base poinls beforc inscallation. <br /> 20. Install posts 3 to 4 (eet apart in critical retention areas and 6 fcet apart in standard applications. <br /> Maintenance Standards <br /> 1. Any damage shall be repaired immediately. <br /> 2. If concentrated flows are evidcnt uphill of the fence,they must be inlercepted and conveyed to a <br /> sediment pond. <br /> 3. It is important to check the uphill side of the fence For signs oFthe fence clogging and acting as a <br /> bamer to flow and then causing channelization oC Rows parallel to the fence. lf this accurs, <br /> replace the fence or remove the trapped sediment. <br /> 4. Sediment deposits shall either be removed when the deposit reaches approximately onc-third thc <br /> height of the silt fence,o�a sccond silt fence shall be installed. <br /> 5. 1C thc filter fabnc(geotextile) has deteriorated due to ultraviolet breakdou�n, it shall be replaced. <br /> Volume II—Conshuction Stormwater Pollution Prevention <br /> 3-56 <br />