Laserfiche WebLink
, {„ — <br /> F <br /> `Y� � <br /> O� Cyt <br /> '>H Vi ,.. .. <br /> y�� � � <br /> " y�" OUBL/C f�f/O/�K5 <br /> yy� <br /> '�yH ^ <br /> � � _...s._ � �� <br /> � Q� <br /> ryO H _.... .._._........._ <br /> �I��g <br /> ^,w �❑ <br /> sy s August 2, 1991 <br /> t" <br /> � <br /> hi H <br /> gti <br /> H <br /> n�y Mr. John Gilles <br /> `" 6103-172nd S.W. <br />� y yo y Lynnwood, WA. 98037 <br /> Ij RE: Owner: John Gilles I <br /> JoU Address 5605 Broadway I <br /> Plan Check No. 91/27201 ' � <br /> Dear Mr. Gilles: <br /> � <br /> III In response to your application for a construction permit, yout plans have � <br /> i been examined and you are advised that the issuance of a permit is bein� I <br /> wi.thheld for the reasons listed below. <br /> v�l. All rooma are required to be labeled as to their use (i.e. , <br /> Uathroom, bedroom, kitchen, livin� room, family room, garage, etc.). I <br /> II�I �C'� �v��� � Floor framing plans shall be included in Plan Set for each floor � <br /> . � level. Foundation Plan does show framing of floor at main level; I <br /> i �"�a�i�5r however, there is no indication of floor framing of upper level. <br /> �_ , W��t. ¢S (May be show ain Floor Plan.) Show beams and any special � <br /> � p�y,,ria� framing, such as at stairs. Indicate size, species and grade of all I <br /> � fram ing mem�e s, inc u ing b e a m s, g i r d e r s, j o i s t s. <br /> The typical wall section shows 4 different sizes of rafters and <br /> � ,joists. If different size members are used, it must be indicated on I, <br /> ' �I �'� plans where each differenl- size member is used. II <br /> � Also, 2X6 ceiling joists will not span the full depth of the house <br /> I 1�'�' � as indicated on the Roof Framing Plan. i <br /> T� <br /> City of Everelt Minimum Requirements Checklist r�equires building <br /> section(s), stair__section and a _fireplace section which were not <br /> (I �� I included in plan set. <br /> t. � �, <br /> On Sheet 6 of the plan set, a brick veneet detail is included; <br /> however, there is not sufficient information included in the plan � <br /> set to check that the footing shown is sufficient to support the <br /> 1 ��� loads imposed from the weight of the bricks. Typically the footing <br /> \ is increased in width a.: least by the depth of the bricks used, as i <br /> i= i <br /> Y v+' l . <br /> I <br /> CITY OF EVERETT•3200 Cedar Street•Everelt,WA 98207 • (206)259-8800• Fax(206)259•8882 `� <br />