My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5831 BROADWAY 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
5831
>
5831 BROADWAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2017 9:28:46 AM
Creation date
1/24/2017 9:28:30 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
5831
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> � �a�l.y,�;;;.!,;�, ENGINEERING/PUBLIC SERVICES <br /> u/s/io <br /> Inspecfion obsc�vatinns Rc: <br /> I3asemenl /►Ilera[ions constructecl wilhoul permits at 5E33] 13roachvay <br /> Ava livcrc�r. wn. ���►�►»�c �► wclo�o-ao� <br /> An inspection of the property at 5831 Broadway Ave.was performed 11/5/1�by two members of <br /> the Everett Building DepL [lectrfcal Inspector Dave Mfsnerand Chief Inspector Ted Budden. These <br /> inspectlons have been performed at the request of the owner to obtain approval for the occupied <br /> space that has been created in the basement of the existing house. <br /> The following summary of the(nspection observations has been created to address the main issues <br /> of Code non-compllance observed at the prooerty.This summary is not intended to be an all <br /> inclusive Iist o(the potential requirements to bring lhe property into compflance. <br /> 1. Electrical pennit to be obtained for all work. (existing noncompiiant work and any corrective <br /> work) <br /> 2. A State Iicensed elecUical contractor is required to"meger'all circuits and provide as built <br /> dra�vings per N[C 2008.Or all wirin�must be expos��d for Inspection. <br /> 3. Electrical service panel needs proper working clearante. <br /> 4. Service panel needs bonding jumper. <br /> 5. Some receptades have been wired incorrectly. <br /> 6. Receptacles require corrrct spacing per NEC 2008. <br /> 7. The room tha[has Been�reated for sleepfng purposes lacks the required resaie and egress <br /> � openmg. A code tompliant egress opening is required,or the room should cease to be ased as a <br /> sleeping room. <br /> 8. Smoke alarms to be provided throughout the dwelling per minfmum code requirements. i <br /> 9. The egress door locks that have interior key feature are ro be removed and provided with I <br /> approved hardware. <br /> ENGINEERING/PUBLIC SERVICES• 320D Cedar Street •Everell WA 98201•425•257-BO10•Fax 425-257-085 I <br /> y <br />
The URL can be used to link to this page
Your browser does not support the video tag.