My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6411 BROADWAY 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
6411
>
6411 BROADWAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2017 9:51:00 AM
Creation date
1/24/2017 9:50:25 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
6411
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . ( �_ <br /> o�„n��y <br /> 1. 1'he basement should bc listed as a U-1 Occupancy in the code dara secdon. <br /> Section 312.1 <br /> 2. The foilowing comments address the one-hour occupancy separation betwcen the <br /> R-1 and U-1 Occupancies: <br /> a) The door at the top of the stairs between the garage and first floor should be <br /> shown as a minimum one-hour assembly. Section 3023 I <br /> b) The wood-framed garage walls supporting the horizontal occupancy separation <br /> should be of one-hour construction (5/8" gypsum sheathing on the exterior). <br /> Section 302.2 <br /> c) The garage, first floor and roof of the stair enclosure shouid be protected by <br /> minimum one-hour construction (unless a one-hour door is placed at the bottom of I <br /> the stairs, then only the garage level walls would be required for one-hour fire- � <br /> resistance). Section 302.3 <br /> d) The garage beam supportin� the first floor should also be wrapped with a layer <br /> of 5/8" type X GWB. Section 302.2 <br /> 3. A smoke detector should be shown centrally located on the first floor. Section <br /> 310.9.1.4 <br /> Construction <br /> 1. Blocking or a rim joist should be shown at the floor/ceiling assemblies and wall <br /> (plan left side) at detail 4/10. Sections 708.2.1 & 2320.8.3 <br /> 2. The location of the 22" z 30" attic access opening for each attic area should be <br /> shown on the plans. Section 1505.1 <br /> 3. Safety glazing should be shown for the bathroom window leading from bedroom kl <br /> in the upper floor 2-bedroom alternate. Section 2406.4, Item 6 <br /> 4. Attachment details of the brick veneer should be provided. Section 1403.6.4.2 <br /> 5. The exterior guardrails should be shown at a minimum of 42" high. Section 509.1 <br /> Mechanical <br /> 1: If the water heaters have nonrigid water connections and are over 4' in height, they <br /> should be shown anchored or strapped to resist earthquake motion. Section 304.4, <br /> UMC <br /> 2. The clothes dryers should be shown vented to the outside. Section 504.3.1, UMC <br /> 2 <br /> 1, <br />
The URL can be used to link to this page
Your browser does not support the video tag.