My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6616 BROADWAY 2018-01-02 MF Import
>
Address Records
>
BROADWAY
>
6616
>
6616 BROADWAY 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:34:14 PM
Creation date
1/24/2017 10:03:53 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
6616
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12 j. <br />When three or more exits are required, no more <br />than two required exits should exit into the <br />same exit system. Section 3317 (h). <br />121. <br />No point in a room in a building should be more <br />than 75 feet to an exit corridor, enclosed stair• <br />way or exterior of the building. Section 3317' <br />(c). <br />121. <br />Exiting through adjoining rooms should comply <br />with Section 3317 (d). <br />123. <br />Panic hardware is required on exit doors serving <br />rooms containing more than 100 occupants <br />and in corridors of Group C Occupancies. Sec. <br />tion 3317 (j). <br />124. <br />Every room in a Group D Occupancy should have <br />access to at least two fecal means of egress. <br />Section 3318 (a). <br />12-5 <br />Doors from bedrooms and wards of Group D <br />Occupancies and all exit openinrs where non, <br />ambulatory patients are housed should have a <br />minimum clear width of 44 inches. No pro. ' <br />jections in this width are allovred. Section 3318 <br />126.1 <br />Panic hardware is rrquircd on exit doors serving <br />more than 50 occupants in Group D OoCUpan. <br />eies unless there is no latch or lock. Section <br />3313 (f). <br />FLOOR, ROOF CONSTRUCTION, COVERING, <br />SKYLIGHTS, ROOF STRUCTURES <br />127. <br />The space between wood floor construction and <br />a suspended ceiling below should be divided <br />into areas not exceeding 3000 square feet. <br />Section 2517 (e!. <br />12?. <br />Attics of combustible material should be divided <br />into areas lint exceeding 3003 (9000) square <br />fee'. Section 3205 (b). <br />129.1 <br />Roof drainage should be conducted under the <br />public sidewalk. Section 3207 (e). <br />13D. <br />Overflow drains having the same size as roof <br />drains and on independent drain lines are re <br />quired. In lieu of this, overflow scuppers three <br />times the size of roof drains should be installed <br />in parallel walk. Overflow system should have <br />inlets located 2 inches above the low points <br />of the roof. Section 7207 (c). <br />131. <br />The aggregate area of penthouses and other roof <br />i <br />structures cannot exceed 331/3 percent of the <br />supporting roof area. Section 3601 (b). <br />nRE.EXTINGUISHING SYSTEM <br />132. <br />An approved automatic lire -extinguishing system <br />in Ilre........................................... is required. <br />` <br />Section 3802 (b). This Includes blinds aces <br />enclosed wholly or pally by combustible con. <br />struclion. <br />133. <br />Dry standpipes are required in buildings four or <br />more stories in 11001t. Section 3803. <br />I.M.IWel <br />standpipes are required as specified in Sec. <br />Pion 3804. <br />135.1 <br />Cotobinalion standpipes are required in build• <br />ings exeeding 150 feet in height. Section 3805 <br />136. Buildings six stories or more in hriglt should be <br />rrovided with not less Than one standpipe dur. <br />ing construction. Suction 3806 (b), . <br />): 7. fireti•krll!I;Illaling syslrnt plans should be sub. <br />' <br />milled to you to delrnuine compliance with <br />applicable budding, plumbing, and fire codes. <br />^yrye�.1!�•.�^.Y�-..a_.i..�r--ter-a .�^'..�,..�s__ <br />- <br />/•?- o - 7A <br />FIREPLACES AND CHIMNEYS <br />138. <br />Chimneys should comply with Sections 3703 <br />and 3704. <br />139. <br />lireplares and barbecues should comply with <br />Section 3707. <br />FINISH 1YORR <br />140. <br />The interior wall and ceiling finishes should be <br />specified and comply with Table No. -12.0 and <br />Section 4203. <br />141. <br />Gypsum wallboard (interior lath and plaster) <br />cannot be installed on wenlher-exposed sur- <br />faces. Sections 4705. 1711. See Section 424 <br />for definition of weather exposed surface. <br />142. <br />Skylights should comply with Chapter 34. Plastic <br />skylights are allowed only under the conditions <br />specified in Section 5205. <br />143. <br />Glass and glazing should comply with Chapter <br />54. Type and thickness of glass should be <br />specified. <br />144. <br />Glass and glazing in hazardous locations should <br />comply with Section 5406. <br />STRUCTURAL <br />745. <br />Special inspection in cunformance with Section <br />305 is required for the following work: <br />(a) Structural concrete where the design is <br />based on an ultimate compressive strength <br />in excess of 2000 pounds per square inch. <br />(b) All welding except where done in the shop <br />of an af:pruved fabricator. <br />- <br />(c) Installation of high strength bolls. <br />(d) Prestressing work. <br />(a) Masonry work required by Chapter 24. <br />146. <br />Soil.classilication in conformance with Table No. <br />28 8 and ............................ pounds per square <br />foot soil hearing value used in design should <br />- <br />be specified on plans. Section 2905 (a). <br />147.1 <br />The foundation investigation report mentioned in <br />plans was not included in data forwarded to us. <br />It should be submitted for review. <br />148. <br />All masonry or concrete rirntenls resisting sets• <br />mic forces should qualify as reinforced ele. <br />ments. Section 2314 (k) 3. <br />149. <br />Precast concrete wall panels are linlited to an <br />• <br />h/t ratio of 36 (25). Section 2616 (c). <br />150. <br />Wood members may support loads from ma• <br />sonry or concrete only under the conditions <br />specified in Section 2516 (a). <br />151. <br />Structural calculations should be submitted to <br />justify the adequacy of the structural system <br />in resisting seismic and wind loads, and sup. <br />porting dead and live loads. This includes <br />foundations. <br />152.. <br />Justifying calculations and details should be pro. <br />, <br />videdfor <br />............................................................ <br />....................................................................... <br />153.E <br />Roofs shall be designed for snow loads of <br />....... pounds per square foot. Section <br />_ <br />2305 (c). <br />154. <br />The roof should be designed for uplift wind pre%• <br />sures with due consideration for lateral support <br />of compression flanges of flexural mernbers. <br />155. <br />Floor load should consider a 20•pound pnr <br />square foot P:utiliou load. Section 2302 (b).._ <br />15G <br />Idarquees should be designed far a 60-pound per <br />square foot live load. Table No. 23-A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.