Laserfiche WebLink
16, <br />Exterior (court) walls within .................... feet of <br />lines should be of ...............: flour construction. <br />Section .................... 03 (a). <br />17. <br />Openings in exterior (court) walls within ............ <br />feel of property lines should be protected with <br />three -fourths -hour fire assemblics. Section <br />• <br />.................... 03 (b). <br />18. <br />Usable space under the first floor except in <br />Group I (J) Occupancies should be enclosed <br />as required in Section 1703. _ <br />19. <br />construction for structural frame <br />elements in the exterior walls should comply <br />Irire-tesistive <br />with Footnote No. 1 of Table No. 17-A and <br />Section ........................ See Section 1702 for <br />clarification. <br />20. <br />paper should be applied to exterior <br />IBuilding <br />walls as specified in Section 1707 (a). <br />21. <br />Enclosures for floor openings should comply <br />with Table No. 17-A, Section 1705. Details <br />should clearly indicate this. <br />22. <br />Structural members carrying masonry or con- <br />crete walls in buildings over one story in height <br />should be protected with minimum one -hour <br />fire prctection. Section 1708. <br />i <br />23. <br />Nonabsprbcnt finish and backing for tuifel room ' <br />walls and floor should conform with Section <br />1711 (a). <br />24. <br />stall walls should be finished with a <br />(Shower <br />hard, nonabsorbent surface to a height of 6 <br />feet. Section 1711 (b). <br />25. <br />Doors and panels of shower and bathtub en- <br />closure should comply with Section 1711 (a) <br />to W. <br />26. <br />than <br />' Pa rapel walls not less than ................ inches in <br />• <br />I height arc required. 1709. <br />27. <br />Eave overhangs and similar architectural pro- <br />jections should comply with Section 1710. <br />......................._..........__.._..............._........_....... <br />28. <br />Projections beyond the exterior wall should con- <br />form with the least restrictive of the following: <br />(a) A point one-third the distance to the proper- <br />ty fine from an exterior wall. Section 504 <br />b <br />(b) A point one-third the distance from an as- <br />sumed vertical plane located where fire• <br />resistive protection of openings is first re. <br />quired due to location of property. Section <br />. 504 (b). <br />29. <br />Envelope ceilings should satisfy the following <br />conditions [Section 43(17 (b) 6,3: <br />-(a) Should not be used to provide fire protec- <br />tion beam and girders supporting more than <br />one floor. <br />(b) Columns should be individually fire pro. <br />tected.' <br />(c) Duct and outlet openings are limited to 100 <br />square inches in each 100 square feet of <br />ceiling area and should be protected with <br />epptoved fire dampers. <br />(d) Electrical outlet boxes should be of steel <br />and not greater than 16 square inches in <br />area. <br />30. <br />board ceilings in conjunction with fire• <br />resistive assemblies should be supported at <br />JGypsum <br />intervals not exceeding 16 inches. Item 27, <br />Table No. 43-C. <br />-7,6 <br />31. <br />Wood stripping or suspended wood sWems for <br />gypsum board ceilings should be not less than <br />2-inch nominal thickness. Section 4704 (b). . <br />[Section 4703 (b) for wall stripping.] <br />32. <br />Final partition layouts and details should be sub- <br />mitted prior to intdallation to justify compli- <br />ance with occupancy, fire -resistive, structural, <br />and exit requirements. <br />33, <br />Justifying test data in conformance with Section <br />10G or an IC00 research recommendation is <br />required for ....................................................... <br />34. <br />Rooms in which rubbish (linen) chutes terminate <br />should be separated front the remainder of the <br />building with a ono -hour occupancy separation. <br />' <br />Section 1706 (c). <br />35. <br />into rubbish and linen chutes should <br />jOpenings <br />not be located in required exit corridors or <br />stairways. Section ]70G (e). <br />SPECIAL OCCUPANCY REQUIREMENTS <br />Group U <br />36. <br />Occupancies should be of one -hour fire• <br />1B-3 <br />resistive construction if located in a basement <br />or above.the first story. Section 702 (b). <br />37. <br />B-7. Occupancies with an occupant load of 1000 <br />or more should be in Type I, 11, III one hour. III <br />Heavy Timber or IV one•hour buildings. The <br />assembly room should not be in a basement <br />if it contains this high occupant load. Section <br />702 (b). <br />38. <br />The main entrance should front directly upon or <br />have'a 20-foot wide access to a public way at <br />least 20 feet in width. Section 703. <br />39. <br />Light and ventilation should comply with Section <br />705. <br />40. <br />A One -Hour Fire -Resistive Occupancy Separation <br />is required between the boiler or central heat. <br />ing'plant and the rest of the building. Section <br />708. <br />41. <br />Exterior openings for rooms containing a boiler <br />or central heating plant should be protected <br />with three -fourths -hour fire.resistive assemblies <br />that are fixed, automatic• or self -closing if to- <br />Bated below openings in another story or if less <br />than 10 feel from other doors or windows in <br />the some building. Section 708. <br />Group C <br />42. <br />Atmospheric separations should comply with <br />Section 802 (b). <br />43. <br />Use of rooms should be tlanficd. Note that <br />rooms in Divisions 1 and 2 Occupancies used <br />for day care purposes and rooms used for <br />kindergarten• first, or second grade pupils and <br />Division 3 Occupancies cannot be located <br />above the first story. Section 802 (c). <br />44. <br />Special hazard rooms should be separated from <br />Other poitions or the building by not less than <br />a Onedlnur Fire -Resistive Occupancy separa• <br />lion. Seciiun 602 (d). <br />45. <br />One requited exit should front directly upon, or <br />have a 20dool wide access to, a public way at <br />least 20 feet in width. Section 803 (a). <br />46. <br />Sanitary facilities should be provided in accord- <br />ance with Section 805, _ <br />47. <br />1 igld and ventilation should comply with Section <br />805. <br />