My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6624 BROADWAY 2018-01-02 MF Import
>
Address Records
>
BROADWAY
>
6624
>
6624 BROADWAY 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2021 1:53:57 PM
Creation date
1/24/2017 10:06:06 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
6624
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
In accordance with the 2003 Ii3C, retaining wall design should include seismic design <br />parameters. Based on the site soils and assumed wall backfill materials, we recommend a <br />seismic surcharge pressure in addition to the equivalent fluid pressures presented above. A <br />rectangular surcharge pressure distribution of 4H and 8H psf (where H is the height of the wall <br />in feet) should be added for "active" and "at -rest" loading conditions, respectively. The <br />resultant of the rectangular seismic surcharge should be applied at the mid -point of the wall. <br />'Tile lateral pressures presented above are based on the conditions of a uniform backfill <br />consisting of on -site soils compacted to 90 percent of ASTM:D 1557. A higher degree of <br />compaction is not recommended, as this will increase the pressure acting on the wall. A lower <br />compaction may result in settlement of structures supported above the walls. Thus, the <br />compaction level is critical and must be tested by our firm during placement. Surcharges from <br />adjacent footings, heavy construction equipment, or sloping ground must be added to the above <br />values. Perimeter footing drains should be provided for all retaining walls, as discussed under <br />the section on "Drainage Considerations." <br />It is imperative that proper drainage be provided so that hydrostatic pressures do not develop <br />against the walls. This would involve installation of a minimum, 1-foot-wide blanket drain for <br />the full wall height using imported, washed gravel that meets Washington State Department of <br />Transportation (WSDOT) Standard Specification 9-03.12(4) against the walls. If a structure is <br />below the water table, it must be designed for hydrostatic uplift and lateral pressures, as well <br />as soil pressures. Such situations are not envisioned for the project at this time; however, if <br />they do arise, we should be allowed to offer situation -specific recommendations. <br />Floor Support <br />We anticipate that floor slabs will be underlain by suitable native soils, structural fill, or <br />possibly by existing fill. As discussed in the "Site Preparation" section of this report, existing <br />fill soils are considered to be settlement -prone, and we therefore recommend limited removal <br />and replacement of existing fill below floor slabs. <br />Floor slabs should be cast atop a minimum of 4 inches of clean, washed, crushed rock or pea <br />gravel to act as a capillary break. Areas of subgrade that are disturbed (loosened) during <br />construction should be compacted to a non -yielding condition prior to placement of capillary <br />break material. Slabs should also be protected from dampness by an impervious moisture <br />barrier at least 10 mils thick. The moisture barrier should be placed between the capillary <br />break material and the concrete slab. <br />Drainage Considerations <br />All foundation walls should be provided with a drain at the footing elevation. Drains should <br />consist of rigid, perforated, polyvinyl chloride (PVC) pipe surrounded by washed pea gravel. <br />The level of the perforationss in the pipe should be set at the bottom of the footing at all <br />locations, and the drain collectors should be constructed with sufficient gradient to allow <br />0 <br />