My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8223 BROADWAY 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
8223
>
8223 BROADWAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/26/2017 11:31:30 AM
Creation date
1/24/2017 10:43:02 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8223
Notes
PREVIOUS 1932 MOUNTAIN VIEW LN
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
182
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OctoUer 3, 2008 <br />� <br />:NG/NEER/N'G / Fi/BL/l SE/lY/CE5 OEPARTA/ENT <br />Adam Clark <br />Gary Parkinson Architccis <br />2812 Colby Ave <br />Gverett WA 98201 <br />I21:: Owncr: 1'lion�c, Charics <br />Job Address: 8223 IIroadway <br />Plan Checl: No: B0809-038 <br />llcar Adam; <br />In response to your application for a construction permit, your plans have Ucen examined and you <br />are advised that tlic issuancc of a perniit is bcing withhcid for the reasons listcd bclow. These <br />comments address building issucs only. Additional rcvisions, or additions, may be required by <br />other departments (such as Utilities, Planning or Pire). All references refer to die 2006 International <br />Building Code, as amended by thc State of Washington and adopted by thc City of Cvcrett and thc <br />Washington Statc Gncrgy Codc, 200G Rdition, uniess stated otherwise. <br />Li order for the processing of ��our application to continue, it wilf be nec:ssary to provide lhe <br />I3uilding Division wiUi hvo complcle ne�r� sels of drawings reflecting ll�e wrrections requcsted. <br />1. Plcase provide the method to ventilate the bedrooms that complies with IBC 1203.4. <br />2. Please provide the method of ventilation for tlie baths, kitchen and utility roont to provide <br />compliance with the VIAQ code. <br />3. Please provide a method of compliauce with the sound transmission requirements of I[3C <br />1207 for the Ucdrooms. <br />4. Please indicate tl�e requirement for smoke detectors in accordance with 113C 907.2.10. <br />5. ANSI Al 17.1, G04.3 requires a dearance around the water closets. Plcase revise. <br />6. IBC 706.3.9 rcquires Uotli liorizontal assemblies and walls defining a fire area to have a 2 <br />hour firc-resistance rating; tL•ereforc, all walls and tl�e storage room door of the exit <br />enclosure should also be protect��. <br />7. IBC 711.4 rcquires all supporting construction of the 2 hour horizontal assembly to also bc <br />2-hour protected. <br />Plcase preparc a response letter showing where each item in this cormction lettcr is addressed on the <br />plan set. <br />Upon resubmittal of thc drawings, your application will Uc given priority and plan rcvicw will <br />recommence. <br />Alt required submittals shall be of sufficient detail and contain sufficient inforniation to ensure that <br />the proposed structure will Ue constructed in compliance with all adopted codes. <br />Sincercly, � <br />,—��' <br />Stevc Miller <br />Associate �ngineer <br />Ka�.M VJIn110B09-018183171MoMmry) <br />CITY OF EVERETT • 3200 Cedar Street • Everelt, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.