/ ��UeL/C SERY/LE5 JEPARTiNENT <br />Oc�obcr 3, 2008 <br />Adam Clzrk <br />Gary Parkinson Architects <br />2812 Colby Ave <br />Evcrett WA 98201 <br />RIi: Owner: Thorpe, Charles <br />Job Address: 8223 Broadway <br />Pian Check No: 130809-038 <br />Dear Adam; <br />In response to your application for a construction permit, your plans have been examined and you <br />are advised that the issuance of a permit is being withheld for the reacons listed bclow. These <br />comments address building issues only. Additional revisions, or additions, may be required by <br />othcr dcpanments (such as Utilities, Planning or Pire). All references rcfer to the 2006 International <br />Building Code, as amendcd by the Sta(e of Washington and ad�pted by the City of Gverett and the <br />Washington State Gnergy Cocie, 2006 Gdition, unless stateci otherwise. <br />In order for Uic pracessing of your application to rnntinue, it will be necessary to provide thc <br />Building Division wiUi ltvo complete new sets of drawings reflecting the corrections requested. <br />I. Plcase provide thc method to ventilale the bedrooms that complies with 1QC 1203.4. <br />2. Please providc the melhod of ventilation for the baths, kitchen and utiliry room to providc <br />compliance with the VIAQ code. <br />3. Pleasc provide a mcthod of compliancc with the sound transmission requirements of IBC <br />1207 for the bedroams. <br />4. Plcase indicate the requirement for smoke detectors in accordance with IIIC 907.2.10. <br />5. ANSI A117.1, 604.3 requires a clearznce around the water closets. Please revisc. <br />6. IBC 70G3.9 requires both horizontal assemblies and walls defining a fire area to have a 2 <br />hour firc-resistancc rating; therefore, all walls and the storagc room door of the exit <br />enclosure sho�ld also be protccted. <br />7. IBC 711.4 requires all supporting construction of the 2 hour horizontal assemUly to also be <br />2-hour protected. <br />Please prepare a response letter showing where each item in this correction lettcr is addressed on the <br />plan set. <br />Upon resuUmittal of the drawings, your application will be given priority and plan revie�v will <br />recommence. <br />All required s�bmittals shall be of sufficient detail and contain sufficient infonnation to ensure that <br />the proposed structure will be conswcted in compliance with all adopted codes. <br />Sinccrcly, <br />� � _--- <br />fV _ <br />Stevc Millcr <br />Associate C_ngineer <br />Iu�M �f�lla US�xtNf�161E::11kaM+n) � � <br />CITI' OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 �� I�� <br />