My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8223 BROADWAY 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
8223
>
8223 BROADWAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/26/2017 11:31:30 AM
Creation date
1/24/2017 10:43:02 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8223
Notes
PREVIOUS 1932 MOUNTAIN VIEW LN
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
182
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ ��UeL/C SERY/LE5 JEPARTiNENT <br />Oc�obcr 3, 2008 <br />Adam Clzrk <br />Gary Parkinson Architects <br />2812 Colby Ave <br />Evcrett WA 98201 <br />RIi: Owner: Thorpe, Charles <br />Job Address: 8223 Broadway <br />Pian Check No: 130809-038 <br />Dear Adam; <br />In response to your application for a construction permit, your plans have been examined and you <br />are advised that the issuance of a permit is being withheld for the reacons listed bclow. These <br />comments address building issues only. Additional revisions, or additions, may be required by <br />othcr dcpanments (such as Utilities, Planning or Pire). All references rcfer to the 2006 International <br />Building Code, as amendcd by the Sta(e of Washington and ad�pted by the City of Gverett and the <br />Washington State Gnergy Cocie, 2006 Gdition, unless stateci otherwise. <br />In order for Uic pracessing of your application to rnntinue, it will be necessary to provide thc <br />Building Division wiUi ltvo complete new sets of drawings reflecting the corrections requested. <br />I. Plcase provide thc method to ventilale the bedrooms that complies with 1QC 1203.4. <br />2. Please providc the melhod of ventilation for the baths, kitchen and utiliry room to providc <br />compliance with the VIAQ code. <br />3. Pleasc provide a mcthod of compliancc with the sound transmission requirements of IBC <br />1207 for the bedroams. <br />4. Plcase indicate the requirement for smoke detectors in accordance with IIIC 907.2.10. <br />5. ANSI A117.1, 604.3 requires a clearznce around the water closets. Please revisc. <br />6. IBC 70G3.9 requires both horizontal assemblies and walls defining a fire area to have a 2 <br />hour firc-resistancc rating; therefore, all walls and the storagc room door of the exit <br />enclosure sho�ld also be protccted. <br />7. IBC 711.4 requires all supporting construction of the 2 hour horizontal assemUly to also be <br />2-hour protected. <br />Please prepare a response letter showing where each item in this correction lettcr is addressed on the <br />plan set. <br />Upon resuUmittal of the drawings, your application will be given priority and plan revie�v will <br />recommence. <br />All required s�bmittals shall be of sufficient detail and contain sufficient infonnation to ensure that <br />the proposed structure will be conswcted in compliance with all adopted codes. <br />Sinccrcly, <br />� � _--- <br />fV _ <br />Stevc Millcr <br />Associate C_ngineer <br />Iu�M �f�lla US�xtNf�161E::11kaM+n) � � <br />CITI' OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 �� I�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.