My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 N BROADWAY STARBUCKS 2018-01-02 MF Import
>
Address Records
>
N BROADWAY
>
1010
>
STARBUCKS
>
1010 N BROADWAY STARBUCKS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2022 4:09:49 PM
Creation date
1/24/2017 12:08:37 PM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1010
Tenant Name
STARBUCKS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />Envelope• • <br />2012 Washington State Energy Code Comphance Forms for Commercial Budangs including R2 a R0 over 0 stones and all RI RevlAeen eau <br />Project Info Project Address 1210 N 0raa0vay, heratt NA 90201 Date 5/21/2013 <br />Compliance forms For Building Department Use <br />do not require a <br />password to use <br />Instructional and Applicant Name Ar1el eleling <br />calculating calls are Applicant Address 901 Ste Axe Seattle NA 11114 <br />wnfe-protecled <br />Applicant Phone. 0041141•400e <br />Project Description New Building ❑ Addition ❑ Alteration ❑ Change of OcaopentyA'onddionmg <br />Compliance Path Q Prescriptive O Component Performance O Total Building Performance <br />Selection required to enable forms <br />Occupancy Group Q Commercial O Group R - R2 S R0 over 0 stories and all R1 <br />Selection required to enable forms <br />Vertical Fenestration and Total Venial Gross Exterior <br />Skylight Area Calculation Fenestration Above Grade %Venal <br />p complyrng via the Prescriptive path, (rough opening) divided by Well Area times 100 equals Fenestmuor <br />enter values for vertical fenestration' 580.0 + 2568.0 x 100= 22.6% <br />skylights. ymss walls and moron this <br />ENV -SUM worksheet ll complying wo Gross Exterior <br />the Component Performance path, enter <br />these values in the ENV-UA wedsheet. Total Skylight divided by Roof Area limes 100 equals °,° Skylight <br />These values auto -Fill from ENV.UA and <br />amwnte-profectedonEIVV•SUM. 0.0 •t-. 1901.0 X100= 0.0% <br />Vertical VERTICAL FENESTRATION AREA COMPLIES <br />Fenestration Area Fenestration Area <br />Compliance <br />Skylight Area SKYLIGHT AREA COMPLIES <br />Vertical Fenestration Q 5071, or more of the floor area is within a daylight zone per C402A 1.1 <br />Alternates O High Performance Fenestration U-lectors and SHGC per C002.0.1.3 <br />Compliance Method <br />❑ Skylight area 0% or greater. VT•0 40 or greater <br />Single Story Spaces ❑ Skylight effective aperture i%orgreater. provide calculation <br />Requiring Skylights ❑ space eligible for exception <br />Requires a minimum of 50% of floor time to be Who a Skylight daylight zone for specdic <br />space types Refer to C402 2 2 for requirements <br />❑ Project has semi -heated spaces as defined per Ce02AA <br />❑ Applying wall exception to semi -healed spaces <br />1 Semi healed spaces may comply under Prescriptwe or Component Performance compliance <br />Semi•Ilealed Spaces path <br />2 Semi -heated spaces shall be documented separately from other conditioned spaces - provide <br />separate compliance forms for each conddioned space type <br />J Envelope elements separating semi -heeled Imm other conditioned spaces shall comply with <br />exterior themral envelope requirements <br />❑ Welkin Cooler ❑ Walk-in Freezer <br />❑ Refrigerated Warehouse Cooler ❑ Refrigerated Warehouse Freezer <br />Refrigerated Spaces Refngemfed spaces shall comply under the Prescriptive Path only Compliance documentation for <br />these areas maybe combined with non -refrigerated areas in the ENV -PRESCRIPTIVE lam. Refer <br />to C402 5 and C402.6 for requirements <br />Project includes more then one occupancy type and/or level of space conditioning Multiple <br />Mixed Occupancy and/or compliance forms maybe requited. Select all that apply to scope of project <br />Space Conditioning ❑ Commercial ❑ R2 • R0 over 0 stones and all Rt ❑ Refrigerated Space <br />❑ Fully Conditioned ❑ Semi -Healed ❑ Low Energy <br />❑ R2 S R3.0 atones a less <br />'Low energy areas are exempt Imm all thermal envelope provisions and compliance forms for <br />these areas am not required Refer to C101.5 2 for exemption <br />0\ <br />
The URL can be used to link to this page
Your browser does not support the video tag.