EXHIBIT A � <br /> VIOLATION GTATION REMEDIES, CASE N CE13-0306 <br /> 6w � 30&� <br /> Violations Observed and CorreQive Adions <br /> IRC,R113.1 Unlawful acts:Work wac done to construct, alter, demolish and repair the residential structure at <br /> the subject property without review or approval by the building depaitment <br /> IRC,R105.1 Permit required:Work was done to construct,alter,demolish and repair the residential structure at <br /> the subject property. In addition work was done to the electrical,mechanical,and plumbing systems in the <br /> residential strucWre. The work noted was done without permits as required by the IRC <br /> IPMC, 108.1.4: The building was altered and is occupied contrary to law <br /> 1. The two apartments lack the required one hour fire resistive separation as required by code <br /> a. Ttie basement unit will be detommissioned and reclassified as"storage only" <br /> 2. The basement apartment lacks a side hinged egress door <br /> a. This door wil�now be used as storage access only. NOTE:tempered label ink wa� observed <br /> 3. The ezterior entry ro the basement apartment has a steeply sloped ramp/walkway that is steeper than the code <br /> allows for use <br /> a. The basement unit will be decommissioned and reclassified as"storage only" <br /> 4. The basement headroom is lower than the code minimum clearance <br /> a. The basement unit will be decommissioned and reclassified as"ztorage only" <br /> S. The basement sleeping rooms latk the code required egress and rescue openings <br /> a. The basement unit will be decommissioned and reclassified as"storage only" <br /> 6. Smoke alarms were not provided i�the basement area <br /> a. The basement unit will 6e decommissioned and reclassified as"storage only" <br /> 7. Some portions o(the basement lack a required heat source,the ba�ance o(the basement shares its heat source <br /> with the upper apartment's�urnace system,which is prohibited by code <br /> a. The basement unit will be decommissioned and reclassified as"storage only" <br /> 8. An unsafe and unapproved chimney and woodstove installation was observed in the upper apartment unit. This <br /> unsafe chimney passes through a baby's bedroom closet. This installation is a severe (ire hazard and should not <br /> be used <br /> a. All dearances and mmbustibles will bc met and the pipe in the upper doset will be partitioned off <br /> Other Corredive Adions to be Taken <br /> 9. Southern block well @ ramp to have Ax6 wood cap installed <br /> 10. Northem ramp to have minimum 36"reil/wail installed <br /> 11. Four (4) smoke detectors to be installed in bedrooms and bonus room. Two (2)combination smoke and carbon <br /> monoxide detectors to be installed in hallways leading to bedrooms—all in senes <br /> 12. Electrical inspector will be called upon to address all electrical violations <br /> 13. Basement kitchen:the following appliances will 6e removed <br /> a. Range,dishwasher,refrigerator, and range hood <br /> 14. Basement laundry: the (ollowing items will be removed <br /> a. Washer and dryer <br /> ]5. Hasement bath:the following items will be removed <br /> a. Lav/vaniry, toilet,and shower <br />