Laserfiche WebLink
� <br /> , Y"M <br /> ___- =-v-o=c—_----_"'_'____"___-_viceeec vvcceec---cc'vvvecc=oececcec=v=eeeoeccvv____ <br /> WATTSUN 5.2 COM1'ONENT CHECKLIST 03/27/92 <br /> �j�y FILE: B:\059i039.WS IiOUSE ID: TOWNHOUSE DUPLE� <br /> ro x <br /> __________'`____________'___________"_______''____________-________________________ <br /> � M <br /> >y�' Name: Floor Area: 2G5G ft2 <br /> y �3 Address: 6311 CADY RD Heating Type: Electric: Zoned <br /> ,i � Reference: 1991 WF� State Enerqy Code <br /> H 77 <br /> ------------------------------------------------------------------------------__ <br /> o t~nH FRAMING INSPECTION <br /> :� z -----'•---------------•�-----------------------------'-----'------------------ <br /> o Qy d Approved plans: <br /> Are available onsite <br /> ��g __ Air leakage: <br /> z H g Soleplate is caulked or glued to s�.bfloor. Rim joists between <br /> �� stories are caulked/sealed. <br /> y z All holes in building envelope (i.e. exterior ceilings, walls, and <br /> �yy y floors) are caulked/sealed, including all electrical, plumbing, <br /> � d y and HVAC penetrations. <br /> � �r Outlets, switch boxes and recessed fixtures on exterior walls are <br /> �� caulked/sealed with approved sealant, or have foam face gaskets <br /> y y�y installed. <br /> AnX recessed lights are IC rated, air tiqht, and sealed to the <br /> ceiling sheetrock. <br /> Wall framing: <br /> Net wall area: 1764 ft2 <br /> Intermediate framing with studs spaced 16" o.c. , R10 insulated <br /> hea�lers and no isolated cavities which cannot be insulated. <br /> �� '� Structural panels: <br /> '� � All structural sheathing is stamped "Exposure I" or "Exterior". <br /> Windows: <br /> �a � (VINYL + ARGON J50.0 ft2) <br /> (VINYL + ARGON SLGD 66.0 ft2) <br /> Windows are installed as shown on the approved plans. The rough <br /> '.., ,� opening around windows and doors is caulked/sealed. <br /> `' Exhaust fans, spot ventilation: <br /> Bathroom fans are 50 CFM, kitchen fans are 100 CFM. Fan ducting <br /> ... has minimal bends and terminates outside of the building. <br /> ' The whole house exhaust fan is between: 175. 0 and 190.0 CFM. I <br />� (-�' ' The whole house fan is rated at 1. 5 sones or less (unless remotely I <br /> .r located) . <br /> INSULATION INSPECTION I <br /> ----------------------------------------- ------- <br /> ( �� Wall insulation: I <br /> (R19 INT Lap Wood 882.0 ft2) <br /> (R-19 INT + R3.6 RB LJ1P WOOD 882.0 ft2) <br /> . Insulation fills all exterior wall cavities. It is not compressed <br /> ____________'________________________"= Page 1 -`-_-__________________________ <br />