PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Slandard #6C1. <br /> .� <br /> �� Connect side se.ver per Cily Standard #'s 601, 602, 604. <br /> 6. Connect all rooftop downspouls to the side sewer. <br /> �� Connect rooftop downspouts to lhe drainage syslem provided for this lot. <br /> B. Rooflop runoff must bi�discharged to a roof downspout infiltralion system per City o( Everett Storm <br /> Manual 3-2.6.2. The a,�proximale size trench is 3.5'wide,2'deep and 25'long. See attachment for <br /> more details. <br /> 9 The contractor must meet with the Public Works Inspector to discuss potential drainaye routing pnor to <br /> beginning Ihe projer,t. <br /> 10. Inslall erosion conlrol measures as determined by the Public Norks inspector, such as silt fence, slraw <br /> bales, swales, or erosion b'ankets. <br /> � Install erosion control measures per City of Evr.rett Standards for small parcels <br /> 12. Remove erosion control measures upon completion o(lhe project prior to final approval of the permil. <br /> 13. All excavaled material(rom fcundalion, sidewalk and driveways shall be hauled to an approved, <br /> permitled sile. No wasting of material is allowed on this building lol. <br /> �� <br /> (14J No dirt, mud, rocks or debris to be tracked onto roadway. <br /> 15. No building materials to be slacked on sidewalks and sidewalks lo ba kept clean and open (or <br /> pedeslrian travel. <br /> 16. Adjust water meler bon 1"above sidewalk grade. <br /> 17 Remove and replace curb, gutter and sidewalk as per City of Everett Standard Plan #'s 305A 8 306 on <br /> Ihis proposal's fronlage as directed by the Public Works Inspector(i.e. all uc�sed driveways and any <br /> broken or damaged area musl be replaced). <br /> 18 Install a Type I concrete drivoway per Cily of Everetl Standard N307. <br /> �9.� Pave driveway from the fronl property line out to the streel paving. <br /> 20. Contact the Water Dislrict for connocling prc:isions for lhis building's water and <br /> sewer services. <br /> 21. A catch basin as per City Standard Plan#402 with a gas Uap per Standard Plan#410 is required for ihe <br /> parking area. <br /> 22 If a sewer pump syslem is lo be installed, lhe pressure line musl discharge into a privale manhole, lhen <br /> �ravily flow across lhe public right-o(-way. <br /> 23. A sprinkler system is required for Oiis building in compliance with the requirements of NFDA Standards <br /> 13D. <br /> FOR PUDLIC WORKS INSPECTION, CALL RANDY AT 425-339-7403/CUFF AT 425-33Y-7404 <br /> � :, �•�,,.,,, ?/ <br /> L <br />