Laserfiche WebLink
�. � __.- . -�._ _ - <br /> , <br /> CAMPIJANCE <br /> . , i � • • � • <br /> RE�UIRED � <br /> INSPECTON �MPOHTANT:Supply Informetlon and check epproprlate clrcles In the shaded boxes. <br /> APPflOVED Dlaregard toplca lhat don't descrlbe your bullding or equlpmsnt.D411.4I:p�ece chacks In <br /> the two left columns. <br /> �� . ��� • . <br /> AA�A <br /> [�] O » Exhaust ventllation ahall be provlded for each dwelling uNt (VIAa, S.303): <br /> ,� .,_ _ , ; . � _ ... . <br /> � Lxatlon Mlnlmum at.25 w.0• Mfr./model Fan Iabef CFM(.1 W.G.) <br /> � Krichenfan 100CFM--ri ENM.�RE 5l s7/ �U <br /> � Bathroom fan(_� 50 CFM N UTOA1� QT 90 Q 0 <br /> „ Bathroom fan(_) 50 CFM �� �� `t� <br /> ` Bathroom fan(_) 50 CFM �� �' ��� <br /> a Laundry fan 50 CFM <br /> Q 50 CFM (1-2 bedrms) � <br /> ia Whole houso 1an 80 CFM (3 bedrms) �� " �` QO <br /> . (choose one) <br /> Q 100 CFM (4 bedrms) <br /> Whole house fan: :.ocation �Rs Snne rating�s fs 1,,if aflic fan cioser than 4'to <br /> ceiling) . ' ��OON ` <br /> Q Whole house fan Is Ifsted/labled"Ier Continuous use". <br /> (� Whofe house fan wiring(or conUol routed to central location (dehum�distat ontyJ. <br /> �j p i9 Whole house fan also sprves as a kitchen or bath spot fan. � Yes � No <br /> (tt a spot fan!s designated as a whole house tan, the capacity shall be tha Iarger C�M roqulrement.) <br /> O O �Whole house fan shai!run contlnuousfy: Kllchon rata 25CFM:8ath&�au� 1ry rate`20CFM <br /> p p i Int9grated torced-alr Iumaco vantllatlon (VIAO Codo,S.303.Y,z{b}) shall pe synchronizad wlth a <br /> whole house ian to suppty fresh air to the rlwellingi, � Yes ' Q No <br /> � 1t yes, a 6"diarleter outside nir Inlet'duct wl motonzetl damp�shail ron trom the bulding ' <br /> e:.Kerioc to the tumace return pienum and limit the ven�illion rate to between .35 -.5 ACH, <br /> �Modif�atlons to the above Inle4lrated}orcod alr eyetem may requlre pe�formance testing, in a <br /> manner acceptable to the buiWirw otficlal, to demonetrate.35- ,5 Air Changos/Hour. <br /> � p Q Mechanlcal ventllatlon lan ducts shall be z 4"and properly sized (VIAo, Table 3-3). <br /> O O � Fresh alr shall be provided fo�each dweUlnp uNt as foilows (VIAQ,S.302.6.1):� <br /> ch bedroomc Tested,screened,conirollable,ihrougn-wall port (2 4 Sq, in.} to the eMe�ior. <br /> ��ach recreatton room:Cne wali port as specified for bodroorr.�. <br /> ther encloseC"habltaCte"r�oms:One wall port es specilicd ior bedrooms. <br /> verall ilving erea:Ooe waU port as specilied tor bedreoms. <br /> I� O Q ;OR�Central torced air turnace which delivers outside makeup air ihrough the duct�ng system <br /> � p Qs Recessed Ilgttting fixtures (5. 502.4.4) ahall comply wl one rr rrwre of the following: <br /> � IC rated, no slots or hol�s ir+cans, caulk.od or sealed between can 2nd celiing <br /> 0 IC rated wlih labla Cedifying an �STM �2fi3 tested alrieakage s 2A CFM <br /> U Arty UL lis�ed tixture eno�osed by a 112"flYPboard t;ox or olher manu(actured hox <br /> w/112'c.learanco to combustahles, :,nd 3"clearance to i��sulation. <br /> WSEC Framing phase requirements: <br /> Inspected by Date <br /> Pagc 4 ot G <br />