Laserfiche WebLink
� . .. ( (� <br /> 26.Roof avsses shall be supponed laterally at points of Ixaring by solid blocking to prevent <br /> rotation and lateral displacement. <br /> 27.Provide calculations for stud walls over 10'0" tall. <br /> 28.Combustion air should be provided to the tumace antl water heater. The method ahould <br /> be shown on the plans. <br /> 29.Domestic clothes dryers shall be vented to the exterior of the building. Note on plans <br /> ducts fbr exhausting clothes drycrs are not to be put together with shat metal screws. <br /> 30.Where eave vents occur, bat�les shall be installed. Bat�les ahall e�ctend 6" vertically <br /> above batts and 12" vcrtically above loose fill insulation. Show on planv. <br /> 31.Specify measures used to limit air ieakage around windows, doorframes, walls 8c <br /> foundadons, walls and roofs, openings at penetradons of utiliry services through walls, <br /> floora and roof, and all other openings in the building envelopc. <br /> Prepare a response letter showing where each item in this correcdon letter ia addressed on the plan <br /> set. <br /> Upon asubmittal of the drawings, your application will be given pdoriry and plan review will <br /> recotnmence. <br /> All required submittais shall be of sufficient detail and contafn sufficient information W ensure tlut I <br /> the proposed suucture will be consqvcted in compliance with ail adopted codes. <br /> Sitx:erely, <br /> �k,L'__ <br /> Jeff ilman <br /> Deve opment Technician <br /> DEDI?LNCIIAISfAME1LMAN/61N CADY 110�0.5CHUCK <br />