. ( <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Stendard�►601. <br /> � 5, y Connecl slde sewer per Cily Standard#'s 601, 602,604. <br /> l�' <br /> 8. Connect ell roo(top downspouts to ihe side sewer. <br /> ,�� Connect roaftop downspouls lo lhe dralnage system provided for this lot. <br /> 8. Rooftop runoH must be discharged to a roof downspout InFlltratlon syslem per City of Everell Storm <br /> Manual 3-2.6.2. The approximale size lrench is 3.5'wlde,2'deep and 25'long. See attechment for <br /> more detells. <br /> 9. The conlractor musl meet with the Public Works Inspector to discusq potentiai drelnage rouling prlor to <br /> beginning Ihe projecl. <br /> 10. Install erosion conlrol measures as determined by the Public Works Inspector, such as sllt fence, sirew <br /> bales, swales, or eroslon blankets. <br /> 71, Install erosion control measures per City of Everett Standards for small parcels <br /> 12. Remove erosion conlrol measures upon complelion of the proJect prior to flnal approval of the pertnit. <br /> 13. All excaveted materlal from foundation, sldewalk and driveways shell be heuled to en approved, <br /> permitted site. No wasting of material is ellowed on ihfs bullding lot. <br /> � 14.' No dirt, mud,rocks or debris to be tracked onto roadway. <br /> 15. No building materials lo be stacked on sidewelks and sidewalks to be kepl cleen and open for <br /> pedestrian travel. <br /> 16. Ad)ust waler meter box 1"above sldewalk grade. <br /> 17, Remove end replace curb,gutler br�d sidewelk es per Cily of Everett Standard Plan#'s 305A 8 308 on <br /> thfs proposal's frontage as directed by the Public Works Inspector(i.e.all unused driveways and any <br /> broken or damaged area must be replaced). <br /> 18. Inslall a Type I concrete driveway per City of Everett Stendard q307. <br /> 19. Pave drfveway from the front property Iine oul W!he streel paving. <br /> 20. Contact the Water Dlslricl for connecting provisions far lhis building's water and <br /> sewer services. <br /> 21. A catch basin as per City Standard Plan t1402 wilh e gas irap per Stendard Plan 11470 Is requlred for lhe <br /> parking area. <br /> 22. If a sewor pump system is to be Inslalled, the pressure Ilne must discharge inlo a private manhole,lhen <br /> gravity flow across lhe publlc righl-of-way. <br /> 23. A sprinkler system is required for this bullding in compliance wilh lhe requirements of NFDA Stendarda <br /> 13D. <br /> � <br /> al� <br /> PWCommenU <br />