My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1418 E CASINO RD 2016-01-01 MF Import
>
Address Records
>
E CASINO RD
>
1418
>
1418 E CASINO RD 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2017 10:55:15 PM
Creation date
1/24/2017 10:54:41 PM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
1418
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Glazing Schedule � ( <br /> P ' cf In/ormefion Confecf Inlormefbn <br /> Paris Fire Restoration BC Investi ative En ineers <br /> 1418 E Casino Rd 3605 C St NE,Aubum,WA 98002 <br /> Everett,WA 98203 253.833.5557 <br /> Conditioned Floor Area 1379 Sum of UA for Heating System Sizing 58.8 <br /> Sum of All Glazing Areas From Below 147 <br /> Glazing to Floor Area Ratio 10.7�0 602.7.2 Exception Ratio(not to exceed 1%)� <br /> Exterior poors <br /> Plan Component Door Percent Width Height Glazing Door poor <br /> ID Descri tion Ref. U-factor Glazed Qt. Feet �"`" Feet '"`" Area Area UA <br /> M Livin Room 0.200 1 2 8 6 ° 16.7 3.3 <br /> One Exem t Swin in Door< 24 S uare Feet 0.200 1 3 6 ° 20.0 4.0 <br /> Sum of Glazing Area, Door Area, and UA(do not inch�de exempf door) 16.7 3.3 <br /> Area Weighfed U= UA/Area 0.20 <br /> Sum olArea and UA lor Heating system size only(include exempt door) 36.7 7•3 <br /> Vertical Glezing(Windows,Glazed doors uslnp Exceptlon 602.8 N1) <br /> Plan Component Glazing Width Height Glazing <br /> ID Descri tion ReL U-factor �t. Feet '"�' Feet '""' Area UA <br /> M Livin Room noAh wall 0.350 1 9 4 36.0 72.60 <br /> M Master Bedroom north wall 0 350 1 6 4 24.0 8.40 <br /> M Master Bedroom west wall 0.350 2 2 2 8.0 2.80 <br /> M Kitchen west wall 0.350 2 2 2 8.0 2.80 <br /> M Kitchen weslwall 0.350 1 1 1 '.0 0.35 <br /> M Kitchen south wail 0.350 1 2 2 4.0 1.40 <br /> M Utilit south wall 0.350 1 3 2 6.0 2.10 <br /> M Utili east wall 0.350 1 3 2 6.0 2.10 <br /> M Bath 0.350 1 1 2 2.0 0.70 <br /> M Bedroom 0.350 1 5 4 20.0 7.00 <br /> M Livin Room east wall 0.350 1 4 4 16.0 5.60 <br /> U Bonus Room north wall) 0.350 1 4 2 t3.0 2.80 <br /> U Bonus Room south walt 0.350 1 4 2 8.0 2.80 <br /> Sum ol Area and UA 147.0 57.45 <br /> Area Weighted U= UA/Area 0.35 <br /> WSEC Prescnplive Worksheet(2006 editionl Zone 1 Glezing Schedule <br /> WSUEEP07-010 Copyright 2007 \ <br /> C�✓ <br />