My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
209 E CASINO RD GYROS TO GO 2018-01-02 MF Import
>
Address Records
>
E CASINO RD
>
209
>
GYROS TO GO
>
209 E CASINO RD GYROS TO GO 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2020 1:36:11 PM
Creation date
1/24/2017 11:52:59 PM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
209
Tenant Name
GYROS TO GO
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> Pueuc woR�rs <br /> February 16, 2012 <br /> Larry Buder <br /> 520 Pine St #104 <br /> Edmonds, WA 96u20 <br /> RE: Owr�er: Jang Bang ]a <br /> Job �4ddress: 209 E Casino RA <br /> Plan Check No: M1202-007 <br /> Dear Mr. Butler: <br /> In response to your appli�ation for a mechanical rype 1 hood permit, your plans have been <br /> examined and you are advised that lhe issuance of a permit is being withheld for the reasons <br /> listed below. These comments address building issues only. All references refer to the 2009 <br /> International Building Code, as r�mended by the State of Washingron and adopted by the City <br /> of Everett and the Washington State Energy Codc, 2009 Edition, unless stated othenvise. <br /> In orde�for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two rnmplete new sets of construdion <br /> documents reflecting the corrections requested. <br /> 1. The dearance requirements for type ] hoods have been changed �ince the original hoed <br /> was installed. The proposed installation would still comply if the wall framing is metal. I( <br /> the freming is wood, please provide detailing that would comply with IMC 507.9 or 308. <br /> 2. TY�e plans should include the reyuirement for a grease duct leak test in accordance with <br /> IMC 5063.2.5. <br /> 3. The plans should indude the requirement for an additional permit for the hood fire <br /> suppression syslem. <br /> I( you have any questions, please call me al 425-257-7264. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be construded in compliance with all adopted codes. <br /> Sincerely, � , e <br /> . ���'., <br /> i <br /> Steve Miller <br /> Associate Engineer <br /> CITY OF EVERETT • 3200 Cedar Streel • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br /> � FI�.II�.�An�N-\Ulla\II Y�:�� 'i.'^1 t n�rv,Md i J.r <br />
The URL can be used to link to this page
Your browser does not support the video tag.