I � � <br /> � 11/19/99 page 1 <br /> IKarl Best H2973 <br /> Drainage keport <br /> IDeveloped Conditions <br /> BASIN SUMMARY <br /> I <br /> BASIN ID: Prop002 NAME: Prop�sed Site, 2-yr SL-orm <br /> ISCS METHODCILOGY <br /> TOTAL AREA. . . . . . . : 0 . 80 Acree BASEFLOWS : 0 .00 cfa <br /> I RI�INFALL TYPE. . . . : TYPElA PGRV IMP <br /> PRECIPITATION. . . . : 1 . 55 inches AREA. . : 0 . 21 Acrea 0. 59 Acrea <br /> 'i'IME INTERVAL. . . . : 10 .00 min CN. . . . : 86 . 00 98 . 00 <br /> ITC. . . . : 5 . 00 min 5.00 min <br /> ABSTRACTION COEFF: 0.20 I <br /> I PEAK RATE: 0 .21 cfe VOL: 0 . 07 Ac-ft TIME: 990 min <br /> I <br /> BASIN ID: Prop010 NAME: Proposec� Site, 10-yr Storm � <br /> ( SCS METHODOLOGY <br /> TOTAL AREA. . . . . . . : 0. 80 Acres BASEFLOWS : 0 .00 cfs <br /> RI�INFALL TYPE. . . . : TYPElA PERV IMP <br /> IPRECIPITATION. . . . : 2 . 25 inchea AREA. . : 0 . 21 Acres 0 . 59 Acrea <br /> TIME INTERVAL. . . . : ].0 . 00 min CN. . . . : 86 . 00 98 . 00 <br /> I 1'C. . . . : 5 . 00 min 5 . 00 min <br /> ABSTRACTION COEFF: 0 .20 <br /> PEAK R)�1'E: 0 . 33 cfe VOL: 0 . 11 Ac-ft TIME: 990 min <br /> ( BASIN ID: Prop100 NAME: Proposed Site, 100-yr Storm <br /> I SCS METHODOLOGY <br /> 'COTAL AREA. . . . . . . : 0. 80 Acres BASEFLOWS : 0 .00 cfe <br /> FAINFALL TYPE . . . . : TYPElA PERV IMP <br /> I PRECIPITATION. . . . : 3 . 25 inchea AREA. . : 0 . 21 Acres 0 . 59 Acres <br /> TIME INTERVAL. . . . : 10 .00 min CN. . . . : 86 . 00 98 . 00 <br /> TC. . . . : 5 . 00 min 5 . 00 mi.n <br /> ( ABSTR1aCTION COEFF: 0 . 20 <br /> PEAK R11TF : 0 . 52 cfs VOL: 0 . 18 Ac- ft TIME: 490 min <br /> I <br /> I <br /> I <br /> I � <br /> D <br />