Laserfiche WebLink
i <br /> � <br /> � <br /> i <br /> � <br /> � <br /> . � � --�, �I <br /> ��;�e;ett ; <br /> Donald R. Westlin, Architect ' <br /> January 8, 1990 � , ! I <br /> Page Six �� � <br /> � <br /> �. Roof elements should be designed for uplift wind pressures in <br /> accordance with Section 2311(d), Formul.a (11-1) and Tatle No. 23-H. <br /> �C1. Prefabricated wood truss calculations and drawings should be reviewed <br /> and approved by the architect prior to submittal to the 6uilding <br /> department. <br /> .Jr� Walls and Ploor separating dwelling units in the same building should <br /> be oP not less than ane-hour fire-resistive construction. Section <br /> 1202(b). <br /> � A Group R, Division 1 Occupancy rnore than two stories in height or <br /> having more then 3,000 square feet above the Pirst story should be <br /> one-hour Pire-resistive construction throughout except as provided in <br /> Section 1705(b). Section 1202(b). <br /> �Mechanical ventilating systems in baths are required to provide five <br /> air changes per hour directly to the outside. Section 1205(c). <br /> �ii�M approved automatic sprinkler system should be installed in <br /> apartment houses that are three or more stories in height or contain <br /> more than 15 dwelling units. Section 3802(h). <br /> � Provide details for the ventilation of clothes dryers, range hood <br /> Pans, utility closet fans and bathroom fans. <br /> In order for the processing oP your application to continue, it will be <br /> necessary to provide the Building Department with two new sets oP drawings <br /> reflecting the corrections requested. <br /> Upon resubmittal of the drawings, your application will be given priority and <br /> plan review will recommence. <br /> All of the above inPormation shall be of suPficient detail and contain <br /> sufPicient inPormation to ensure that the proposed dwelling will be , <br /> constructed in compliance with the City Building Code. <br /> I <br />