Laserfiche WebLink
Fire alarm systems shall be installed under permit of the City of Everetl Engineering 8 Public <br /> Scrvices Department. Electrical inspections and approval are required prior to calling for <br /> acceplance tests. Call (425) 257-8810 for permit information. <br /> The absence ot working phone linea for the alertn syetem will be cause for postponing Fire <br /> Deparlment inspection and testi�g and shall result in denial of occupency. <br /> 41. No. 3021-07, Chapler 18.76, of the Everelt Municipal Code. The ayatem must include a <br /> mechanical water gong bell. <br /> Plans for any such system shall be submltted to the Engineering 8 Public Services <br /> DepaAment for examination and approval. Such plans shell include plans for the <br /> underground mains that wil� supply the sprinklar system. <br /> The type of sprinkler to be inslalled will be determined by the Building Official. It may be an <br /> NFPA 13, NFPA 13R, or NFPA 13D system depending upon several tactors. Spri�kler <br /> installation shall not begin without an approved and stamped sel of plana from lhe <br /> Engineering 8 Public Services Department. The Fire Department will also review the plans <br /> and shall field inspect the installation based only on approved plena that muat be on site. <br /> Changes to plans must be approved by both the Engineering & Public Services and Fire <br /> Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as eslablished in NFPA <br /> Standard 13. Underground piping ahall be hydrostatically teated and Ilushed es established <br /> in NFPA Standard 24 for private fire mains. (Below•ground piping must be installed by <br /> Washington State Petrol Licensed Underground Sprinkler line certified "U"installers. For <br /> fuAher information, co�taot the State Fire Marshal's Office et (360) 570-3134 or contact the <br /> Everett Fire DepaAmenl at (425) 257-8123.) All such tests shall be witnessed by e Fire <br /> Departmont Inspector. Cell (425) 257-8124 to make an appointment for inspection. <br /> Contractors' materials and test cerlificales shall be submitted to the Everett Fire Department <br /> prior to issuance oT any Certifcates of Occupancy. <br /> 42 Construction and dem�lilion oi buitdings shall be in compliance with the provisions of the <br /> 200G International Fire Code, Chapter 14. <br /> �� 43. Buildings containing high-piled combuatible storage shall be in accordance with Chapler 23 <br /> of the 2006 International Fire Code end NFPA 13. A Fire Department permit fs required for <br /> high-piled storage. <br /> 44 Permits are requira�+rom the Fire Department for removal end installation of underground <br /> fueltanks. <br /> 45. Abandoned tanks shall be pumped out and ihe fuel property disposed of prior to removel. <br /> No product or ri�se waler may be diaposed ot in such a way thal il could entar lhe storm <br /> drains system. <br /> 46. The location of Fire Deparlment connections (FDC)and posl indicalor valves (PIV) shell be <br /> determined by the Fire Code Official. It immediate outside mandoor accass is evailable to <br /> the sprinkler valves (risers), a PIV will not be required. <br /> , iy// <br />