Laserfiche WebLink
( <br /> � <br /> I� � <br /> �� � ,. ;,_> >�t� ' <br /> ,. . � _ _ _ , � <br /> FRANKLIN � . � � �25 ��� E252 <br /> ENGINEERING � � �� - �� �� � . ���� � ' �°m <br /> �.�f �t ���,I' :. : �. �:� i '��tr <br /> I�80F� '(%�- (r <br /> May 13, 2008 <br /> ENVELOPE SUMMARY <br /> RE: Magnum Energy TI <br /> 2211 W Casino Rd <br /> Evcrett, WA <br /> Tenant improvement of shell building to heated space. Project complies wit`� 2006 WSEC <br /> using the Component Performance approach with heating by Other Fuels. <br /> Vertical Glazing: Double pane, 1l2" 3ce Air, low-e10'01, fixed. Or certified tested <br /> assembly per NFRC. U=0.55, Jefault ITable 10-61. SHGC=0.45. I <br /> i <br /> Doors (Opaquel: Insulated metal, U =0.60, default ITable �0-61. <br /> Other Rooi: R-21 rigid insulation on wood deck. U =0.044, calculated. <br /> Wall k1 IOpaquo, Floor to 9'-0" AFF in Office; Floor to 10'-0" AFF in Temp. Control►: <br /> Concrete, min. 6" thick, furred with wood or metal studs, 2x4, 24" oc with R-11 <br /> batt insulation, U =0.115, �alculated. � <br /> Wall ff2 (Opaque, 9'-0" to struc!ure above in Office, 10'-0" to Rooi in Temp. Control, All <br /> in Warehouse except as noted in Wall ti41: Concrete, min. 6" thick, with R-1 1 batt <br /> insulation stickpinned to concrete, U =0.Q87 calculated. <br /> Wall J/3 (Opaque, Demisingl: Metal studs, min. 5-1/2", 16" oc with R-19 batt insulatio�, <br /> U =0.109 default (Tabte 10-5A1. <br /> ,. <br /> i <br /> i ' <br />